497931
81
Zoom out
Zoom in
Previous page
1/90
Next page
Premier 412 & 816 Installatie Handleiding
INS159-6 81
6. Specificaties
Alarm centrale
Voeding
Maximum Stroom
16.5V
AC, 25VA transformator: 1 ADC
16.5V
AC, 40VA transformator: 1.5ADC
Rimpel:
<5%
Zie Installatie en Veiligheids Notities
Electrisch
Stroom verbruik
In rust :
In alarm:
<50mA
<150mA
Zekeringen
Netspanning (Vanuit fabriek
230V
AC Transformator):
125mA, 250V, 20mm
(Zie Veiligheidsnotities 1 & 2)
Netspanning (Vanuit fabriek
115V
AC Transformator):
250mA, 250V, 20mm
(Zie Veiligheidsnotities 1 & 2)
Batterij:
12 V DC Aux:
Sirene:
Data:
1.6A, 250V, 20mm
1A, 250V, 20mm
1A, 250V, 20mm
1A, 250V, 20mm
Standby Batterij CaARCiteit: 1.2Ah to 7Ah
(Zie Veiligheidsnotities 1 & 2)
Zones
Premier 412:
Premier 816:
EOL Weerstandswaarde:
4
8
3K3
PANEEL Outputs
O/P 1 - Bewaakt:
O/P 2 - Bewaakt:
O/P 3 - 8:
1A geschakeld naar 0V
1A geschakeld naar 0V
100mA geschakeld naar 0V
Sirene Output (Bewaakt)
Speaker Mode:
Sirene Mode:
Minimum load 4
1A geschakeld naar 0V
2-Draads Rook Detectors: ESL429CT
Systeem Sensor 2100TS
Data Bus
+:
—:
T:
R:
+12V
0V
Verzonden Data
Ontvangen Data
Keypads: tot 6
Digitale alarmkiezer
Protocol:
Pulse Format, Express Format,
Fast Format, Contact ID, SIA
Level II, Pager and Mobiele
Telefoon
Telefoon Nummer:
Kies formaat:
REN:
Keuring:
4 tot 24 cijfers
Puls of DTMF
1
CTR21
Omgeving
Werk Temperatuur:
-10°C to +45°C
+14°F to +113°F
Opslag Temperatuur:
-20°C to +60°C
-4°F to +140°F
Maximale Luchtvochtigheid: 95% geen-condensing
EMC Omgeving: Woning/Zakelijk/Lichte
Industrie of Industrie
Physiek
Afmetingen:
282mm x 225mm x 80mm
Keypads
Elektrisch
Werkspanning: 9 - 13.7VDC
Stroom Verbruik
Nominaal:
Volledig verlicht scherm:
35mA
85mA
Zone Indicatie
Premier RKP4:
Premier RKP8:
Premier RKP16:
Premier RKP8 Plus:
Premier RKP16 Plus:
Premier LCD:
Premier LCDL:
4
8
16
8
16
32 Character Standard LCD
32 Character Large LCD
Status Indicatie
Alarm:
Service:
Armed:
Ready:
Fire (RKP8/16 Plus):
Bypass (RKP8/16 Plus/LCD):
Instant (RKP8/16 Plus):
Stay (RKP8/16 Plus):
Rood
Geel
Rood
Groen
Rood
Rood
Rood
Rood
Data Bus: 4-draads tot 250m, serie,
parallel of combinatie
Omgeving
Werk Temperatuur:
-10°C to +45°C
+14°F to +113°F
Opslag Temperatuur:
-20°C to +60°C
-4°F to +140°F
Max. Luchtvochtigheid: 95% geen-condensing
EMC Omgeving: Woning/Zakelijk/Lichte
Industrie of Industrie
Fysiek
Afmetingen:
Premier RKP4/8/16
Premier RKP8/16 Plus/LCD
140mm x 105mm x 35mm
145mm x 115mm x 30mm
Gewicht: 380g
81


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Texecom Premier 816 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Texecom Premier 816 in the language / languages: Dutch as an attachment in your email.

The manual is 4,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info