eZ430-Chronos Software Projects
3.6.4.4 Upgrading Existing eZ430-Chronos Kits
Earlier eZ430-Chronos kits (production date prior to 04/2010; the production date may be found on bottom
of eZ430-Chronos box) do not support the wireless update feature. Therefore, the kits must be updated
manually. In addition to a new version of the PC software, firmware updates of the RF access point and
the eZ430-Chronos watch are required.
3.6.4.4.1 RF Access Point Update
The CC Debugger is required to reprogram the CC1111 based RF access point. To perform the update,
the SmartRF Flash Programmer software is used to on the PC.
1. Solder a debug interface connector cable onto the CC1111 access point as shown in Figure 3-16.
Figure 3-16. eZ430-Chronos RF Access Point Connection to CC Debugger
CC-Debugger RF Access Point
Pin 1 GND
Pin 2 Vcc
Pin 3 P2.2 (DC)
Pin 4 P2.1 (DD)
Pin 7 RST
Pin 9 Vcc
2. Connect RF access point to CC Debugger and press the "Reset". The LED on the CC Debugger
should become green.
3. Launch the SmartRF Programmer software
4. Open .hex file according to frequency in C:\Program Files\Texas
Instruments\eZ430-Chronos\Recovery\RF Access Point
5. Select "Erase, program and verify"
6. Clock "Perform actions"
53
SLAU292DNovember 2009Revised March 2011 eZ430-Chronos Software
Submit Documentation Feedback
© 2009–2011, Texas Instruments Incorporated
53


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Texas Instruments eZ430-Chronos at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Texas Instruments eZ430-Chronos in the language / languages: English as an attachment in your email.

The manual is 7,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info