28
Field
Description
Link Status
Displays currently actual link rates and duplex
modes on switch ports. "--" is displayed if a
port is not linked.
Speed/Duplex
Three types of duplex modes are available on
Ethernet ports:
Full-duplex: Ports operating in
Full-duplex mode can send and receive
packets concurrently.
Half-duplex: Ports operating in
Half-duplex mode can either send or
receive packets at a given time.
Auto: Auto-negotiation, ports operating in
Auto-negotiation mode determine their
duplex mode through auto-negotiation
with peer ports. By default, Auto
(Auto-negotiation) is enabled for the
Speed/Duplex option.
Flow Control
With flow control enabled on both the switch
and its link partner, the switch, when
encountering congestion, will send flow
control frames to notify the link partner of
such; upon receiving such frames, the link
partner will temporarily stop sending packets
to the switch, thus avoiding packets drop and
ensuring a reliable network. Meanwhile, if a
certain port receives Pause frame, it will also
stop sending packets out.
By default, the flow control feature is
disabled.
Enable/Disable
Enable/disable selected port(s). A disabled
port cannot forward packets.
By default, all ports are enabled.
Isolation
Use this option to group ports together to
implement layer-2 data isolation among ports
in an isolated group to, delivering better
security and flexible networking solutions.
Only in 802.1Q VLAN mode can it be
configured. By default, ports are not isolated.
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Tenda TEG3224P at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Tenda TEG3224P in the language / languages: English as an attachment in your email.

The manual is 8,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info