627242
10
Zoom out
Zoom in
Previous page
1/44
Next page
FUNCTION.The CHARGE function permits initial charging STAND-BY power supply unit.
of the battery at constant current with the value previously
set, for a maximum time of 10 hours. If the battery voltage is
= indicates:
#
particularly low, a fixed current of 2A will be delivered until
- No battery voltage
1.5 V/e is reached; once this threshold has been reached
- Low battery voltage
this current until the end-of-charge limits for that particular
= inversion of polarity.
type of battery are reached. Once this time has elapsed, if
H
the battery has not reached a certain battery voltage level
All the alarm conditions prevent the delivery of
(stored inside the microcontroller) a further 2 hours are
current to the battery except for the auxiliary power
added after which the battery charge is switched off. If the
supply unit which is equipped with independent
battery charger reaches the reference voltage before the
safety devices.
end of the 10 charging hours pre-set in the control circuit the
battery charger switches off without adding the extra
PRECAUTIONS:
two hours.
The STARTRONIC battery-charger/starter is a
The START function permit starts at CONSTANT
microprocessor controlled electronic device that is able to
VOLTAGE, automatically limiting the current to the pre-set
protect the vehicle electronics from voltage surges that may
values with cycles lasting "5 sec ON" and "20 sec OFF".
be generated when particularly flat or sulphated batteries
Blinking of the STARTled indicates that this function is
are being charged. In this case its protective capacity is
enabled.
shown as it blocks the charge function every time the ON
key is pressed: a fraction of a second is sufficient to evaluate
(CHARGE) Charge current selection key
the battery status and automatically discontinue charging
This key is used to select the charge current level in
when there is evidence of dangerous voltage surge risks to
"CHARGE" mode .
the automobile devices that are connected electrically to the
The charge currents that can be set are
battery terminals.
WARNING: select the charge voltage in accordance with
2/5/10/20/30 A
the rated voltage of the battery to be charged.
By setting the key to START, the current available is 170 A
for the model ST300.
CHARGING VERY FLAT OR SULPHATED BATTERIES
WARNING: when charging in this situation the automobile
(DISPLAY) Current/voltage key
electronics are not protected therefore it is essential to
Three different displays can be selected with this key:
disconnect the battery from the vehicle. To be able to charge
- "I": the current delivered in Amps is displayed, both in
such batteries it is necessary to exclude the STARTRONIC
CHARGE and START;(ST 300)
built-in protection against voltage surges that could destroy
- "V": in this position the display indicates the output voltage
the vehicle electronics.
to the battery in Volts;
Excluding this option implies that the battery can be
charged if and only if it is disconnected from the automobile
electronics.
To be able to charge without the support of the protections,
FIG.B-C
press the ON key for at least 5 seconds. Pressing the ON
(ON) Switch-on Key
key for more than 5 seconds causes the STARTRONIC to
This key identified by "I" allows to deliver power to the
enter an operating mode without checks on any voltage
battery.
surges that could be generated when the battery being
IMPORTANT: before pressing this button ensure that you
charged is in very poor condition: the charging process will
have previously performed all the required settings.
not stop until either the operator chooses to press the OFF
If the function selected with the key (I) is START, the battery
key or a preset time limit has been reached.
charger will begin to deliver starting current only when
At the end of this stage, which is indicated by the flashing of
requested by the vehicle.
the general alarm LED, the STARTRONIC returns
automatically to protected operating mode which ensures
(OFF) Switch-off Key
the elimination of voltage surge risks.
This key, identified by "O", interrupts delivery of the current
to the battery/batteries during charge or start.
WARNING: the machine is still powered.
_______________(D)______________
ANLEITUNGSHANDBUCH
(E) Battery charge status indicator key
The three leds indicate the battery status by reading its
voltage. The upper led indicates that the battery is charged
by reading a battery voltage equal to or higher than the end-
of-charge voltage. The middle led indicates that the battery
is still able to receive current but that the charge level is
acceptable. The lower led indicates that the battery is flat.
(F) Alarms and safety devices key
The equipment is protected against overloads, short circuits
Die Modelle ST 500 und ST 300 sind Monophase
and inversion of polarity by means of internal electronic
Ladegerät/ Starter, Speisung 230 Vac 50/60Hz, das
safety devices.
elektronisch mit konstantem Strom und konstanter
There are 3 leds:
Spannung von einem Mikrokontroller kontrolliert werden:
= cut-in of the thermostatic safety device except for the
Sie ermöglichen die Ladung von Bleibatter ien mit freien
"
ACHTUNG:
VOR GEBRAUCH DER MASCHINE LESEN SIE
SORGFÄLTIG DIE BETRIEBSANLEITUNG
ST 500-300
- 10 -
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Telwin STARTRONIC 330 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Telwin STARTRONIC 330 in the language / languages: All languages as an attachment in your email.

The manual is 1,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info