627239
3
Zoom out
Zoom in
Previous page
1/52
Next page
low values according to the capacity and condition of the
5. BATTERY CHARGER PROTECTIONS (FIG. D)
battery.
The battery charger is equipped with protection in case of:
FIG.B
- Overloads (too much current delivered towards the
battery).
NOTE: Once the battery is charged you may note the liquid
- Short circuit (charging clamps set in contact with one
inside the battery starting to “boil”. It is advisable to stop
another).
charging when this phenomenon appears so as to prevent
- Polarity reversal of the battery.
damage to the battery.
- For battery chargers equipped with fuses, it is necessary,
in case of substitution of fuses, to use spares having the
By means of the switch, select the charge current according
same nominal current value as the fuse changed.
to the type of battery and its charge condition. This value is
WARNING: If fuses with current values different
shown by the ammeter on the scale with the lower value.
Note that slow charging is the best guarantee for longer
from those given were used damages to persons and
battery life as there is less heating, thus preventing plate
things could be caused. For the same reason do not
oxidation and electrolyte boiling.
substitute the fuse with copper (or other materials)
The ideal current value is 1/10 the ampere-hour power of the
bridge.
battery. For example, for a 40 Amp battery the optimum
The substitution of the fuses is to be done when the
charge current is 4 Amps.
mains cable is disconnected from the mains.
Simultaneous charging of several batteries
6. USEFUL ADVICE
This operation must be performed with great caution:
- Clean the positive and negative terminals of possible
WARNING; do not simultaneously charge different types of
oxidation so as to ensure good contact with the clamps.
batteries or batteries with different capacities or levels of
- Never ever allow the two clamps to come into contact
discharge.
when the battery charger is plugged into the mains. If you
If you have to charge more than one battery at the same time
do the fuse will blow.
you can connect them “in series” or “in parallel”. Between the
- If the battery charger is used with a battery which is
two systems, we recommend connection in series because
always connected to a vehicle, check the instruction
you can easily check the current charging each battery, as it
and/or maintenance manual of the vehicle under the
will be the same as that shown by the ammeter.
paragraph: “ELECTRIC SYSTEM” or “MAINTENANCE”.
Before charging it is advisable to disconnect the positive
NOTE: If two batteries with rated voltages of 12V are
cable which is part of the electrical system of the vehicle.
connected in series, the battery charger MUST be set to the
- Check the battery voltage before connecting it to the
24V position.
battery charger. Remember that 3 caps correspond to a 6
FIG. C
volt battery, while 6 caps to a 12 volt battery. At times you
may have two 12 volt batteries. Sometimes there may be
END OF CHARGE
two 12Volt batteries in series, in which case a voltage of
- Remove the power supply from the battery charger by
24Volt is required to charge both accumulators. Make
turning the switch to OFF (if present) and/or removing the
sure they have the same specifications to prevent uneven
power supply cable from the mains outlet.
charging.
- Disconnect the black charge clamp from the chassis of
- Before proceeding with starting, carry out a rapid charge
the vehicle or from the negative terminal of the battery (-
for a few minutes: this will limit the starting current, hence
symbol).
also requiring less mains current. Before starting the
- Disconnect the red charge clamp from the positive
vehicle, remember to make sure the battery is connected
terminal of the battery (+ symbol).
properly to the respective (+ and -) terminals, and that it is
- Store the battery charger in a dry place.
in good condition (not sulphated or dud).
- Close up the battery cells with the appropriate plugs (if
Never ever start vehicles with the batteries disconnected
present).
from their respective terminals; the presence of the
battery is essential for the elimination of possible
STARTING
overvoltage that may be generated due to energy
Before starting the vehicle, make sure the battery is
accumulating in the connection cables at the starting
connected properly to the respective (+ and -) terminals,
stage.
and that it is in good condition (not sulphated or dud).
- If the engine does not start, do not insist, but wait a few
Never ever start vehicles with the batteries
minutes and then repeat the rapid charge operation.
- Starting should always be carried out with the battery
disconnected from their respective terminals; the
connected (see the section on STARTING).
presence of the battery is essential for the elimination of
possible overvoltage that may be generated due to
energy accumulating in the connection cables at the
_______________( I )_______________
starting stage.
For starting turn the switch to the start position at the voltage
MANUALE D’ISTRUZIONE
corresponding to that of the vehicle being started.
It is essential, before turning the ignition key, to make a rapid
charge for 5-10 seconds, which will greatly facilitate starting.
Rapid charging should always be done with the battery
charger switched to the charge position and NOT to
AT T E N Z I O N E : P R I M A D I U T I L I Z Z A R E I L
starting.
CARICABATTERIE LEGGERE ATTENTAMENTE IL
It is possible to enable starting by pressing the remote control
MANUALE D’ ISTRUZIONE!
button (only for 3-phase).
The current supplied is indicated on the scale of the ammeter
1. SICUREZZA GENERALE PER L'USO DI QUESTO
with greater capacity.
CARICABATTERIE
WARNING: Before proceeding with starting follow the
vehicle manufacturer's instructions carefully!
- Make sure the power line is protected by fuses or
- Durante la carica le batterie emanano gas esplosivi,
automatic circuit-breakers with sizes as indicated on the
evitate che si formino fiamme e scintille. NON FUMARE.
rating plate by the ( ) symbol.
- Posizionare le batterie in carica in un luogo areato.
- In order to prevent overheating in the battery charger,
ALWAYS carry out the starting operation according to the
duty cycle (work/pause) as indicated on the appliance (e.g.
START 3s ON 120s OFF-5 CYCLES). Do not insist if the
engine does not start: this could cause serious damage to
- L e p e r s o n e i n e s p e r t e d ev o n o e s s e r e
the battery or even to the electrical equipment in the
opportunamente istruite prima di utilizzare
vehicle.
l'apparecchio.
- 3 -
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Telwin ENERGY 650 START at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Telwin ENERGY 650 START in the language / languages: All languages as an attachment in your email.

The manual is 1,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info