Energy 4010 G Vers. 001
20
G
B
7.2 Maintenance not requiring specialised
personnel
To perform this kind of service, it will be
necessary to open the generating set door. The
following precautions must therefore be taken:
1 The generating set must not be in operation,
and all its parts must be cold
2 Let the generating set cool off.
3 Turn the selector switch to the position "ON"
(manual) (Fig.31 Ref.2)
N.B. Remember to switch the selector switch
to "OFF" (automatic) after completing the
required checks.
7.3 Checking the engine oil level
Unscrew the engine oil filler cap and clean the
dipstick (Fig.33 Ref.1).
Put the dipstick back in without screwing.
Take the dipstick out again, and make sure
that the engine oil level is between the two
(min and max) notches. Should the oil level be
below the minimum notch, restore the oil level
using the recommended type of engine oil
(refer to the engine user and maintenance
manual).
Put the dipstick and filler cap back on and
screw tightly.
Do not fill to exceed the
maximum level, as this could cause
malfunctioning of the fuel pump and hence of
the generating set.
All engine oil level
checking operations must be performed with
the generating set in a perfectly horizontal
position.
7.4 Maintenance operations to be carried out
by qualified personnel
To carry out certain servicing operations, it is
possible to extract the engine-alternator
assembly from the front. (See paragraph 4.3.).
This will make it easier to obtain access to all the
inside parts of the generating set for unscheduled
maintenance or repair operations.
7.4.1 Engine oil replacement
Use multigrade detergent oil for four-stroke petrol
engines having a SAE viscosity degree suited to
the climate the generating set is working in (see
table and detailed instructions in the engine use
and maintenance manual).
To make it easier to drain the spent engine oil, it
is advisable to let the engine run for 3 - 5
minutes; in this way, the oil will be more fluid and
emptying will be quicker and more thorough.
For cold climates
For hot climates
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Telair Energy 4010g at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Telair Energy 4010g in the language / languages: English as an attachment in your email.

The manual is 2,91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info