4.2.2 Making a new hole
Choose a central area on the roof, between two
cross members, and mark out a 395 x 395 mm
square using a felt pen (“Fig. 3”) and (“Fig. 5” ref.
1).
The dimensions of the 395 x 395 mm
square on the cardboard template (“Fig.
3”)areprovidedforguidanceonly.Before
cutting the roof, check the actual size of
the hole with a tape measure.
Cut the opening in the roof carefully using a hack-
saw; make sure no electrical wires are severed
(“Fig. 5” ref. 2).
2
1
Fig. 5
Fix a reinforcement frame (not supplied with the
air conditioner) along the perimeter of the opening
(“Fig. 6”).
Fig. 6
Insert a sealant product between the adapter and
the roof; this product must ensure a watertight
seal and perfect bonding of the two parts.
4.2.3 Power cable
A 3-core cable with a 2.5 mm² cross-section (live-
neutral-earth) must be routed for the power sup-
ply of the air conditioner. The wires at one end
must be connected to the thermal magnetic circuit
breaker (recommended load 10A) previously in-
stalled in the vehicle’s electrical distribution panel
exclusively for use by the air conditioner. The oth-
er end should reach the opening made in the roof
of the vehicle and protrude from the hole made in
the reinforcing frame by approximately 50 cm - in
order to facilitate connection to the air conditioner
(“Fig. 7”).
The electrical cable must be suitably protected in
order to ensure its integrity and insulation in all
conditions of use of the vehicle.
- 10 - Rev.011
Translation of the original instructions
DualClima 8400H - DualClima 8400HB - DualClima 8400HN - DualClima 12500H
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Telair 8400H DualClima at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Telair 8400H DualClima in the language / languages: English, German, Dutch, French, Italian, Portuguese, Swedish, Spanish, Finnish as an attachment in your email.

The manual is 17.77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info