480163
3
Zoom out
Zoom in
Previous page
1/20
Next page
3
English
DEFLATION AND STORAGE
1. Make sure the bed is unplugged from the electrical outlet
prior to deflation.
2. To deflate your
AeroBed
®
open the Quick Air Release
Valve at the foot of the bed to release the air in
approximately 15 seconds (1 minute for the
Premier
Raised Pillowtop
).
3. Roll or fold the AC cord with Comfort Control Wand and
secure it. Fold sides of bed into the centre along its length.
Tightly roll your
AeroBed around the pump towards Air
Release Valve end. When the bed is completely rolled, and
all air is expelled, push the Air Release Valve closed until it
locks.
4. Slide the duffel bag over your
AeroBed. Store your
AeroBed in a clean dry place at room temperature (above 50°F/10° C). Storing
your
AeroBed under 50° F (10° C) and over 100° F (38° C) may affect its
performance and will not be covered under guarantee.
5. If a mattress cover and/or valance is included with your bed, it/they may be
removed after deflation. Alternatively, you may store your product with the
mattress cover and/or valance on the bed. Wrinkling may occur.
CARE AND MAINTENANCE
1. Inspect your AeroBed prior to each use.
2. Keep your AeroBed away from any sharp objects. Large cuts or snags may not
be repairable and will not be covered by your guarantee.
3. When not in use, store your AeroBed in a clean, dry place out of extreme
temperatures. Product must be at room temperature prior to inflating.
4. Do not store your AeroBed folded inside sofa beds or roll-aways. This may
cause damage to your bed that will not be covered under your guarantee.
5. In case of incidental damage to your bed, a repair kit has been included. Please
follow repair instructions carefully.
2
English
INFLATION
1. Remove your AeroBed
®
from its lightweight duffle bag. Keep bag for storage.
NOTE: Bed must be at room temperature prior to inflating.
Place your rolled up bed on the floor or other surface free of obstructions or
sharp objects.
2. Make certain the Quick Release Valve located at the foot of the bed is closed.
Bed should be stored with valve in the closed and latched position.
If the Quick Release Valve is open, close it by using 2 thumbs to push cover and
snap into valve. Be careful to avoid pushing valve cover to the right or left as it
snaps into the valve opening.
3. Remove AC plug, cord and Comfort Control Wand from plastic bag and shrink
wrap.
4. Plug into any standard polarized 220-240 volt AC electrical outlet. (Note: this
product is rated at 230V ~ 50Hz, 1A. 110 Volt product sold outside Europe).
Never use with an extension cord unless the plug can be fully inserted.
5. Push and hold the button of the Comfort Control Wand for
approximately 60 seconds (3 minutes for
Premier
Raised Pillowtop
) to inflate the AeroBed to the full
(firmest) capacity. Bed will not over-inflate.
6. If applicable, the Premier Raised Pillowtop and Premier
Comfort
beds should be dressed with their covers' and/or
valance whilst they are still partially inflated.
7. Lie on the bed and use Comfort Control Wand to adjust the firmness to your
desired level. For firmer bed, press inflate/firmer button. For softer bed, press
deflate/softer button.
This is the closed position. Open Air Release Valve.
3 minutes
Close Valve Using 2
Thumbs.
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Tel Sell Aerobed at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Tel Sell Aerobed in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 0,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info