Always disconnect the appliance from the electricity
main before making any adjustments.
All seals must be replaced by the technician at the
end of any adjustments or regulations.
Our burners do not require primary air adjustment.
10) TAPS
"Reduced rate" adjustment
- Switch on the burner and turn the relative knob to
the "Reduced rate" position (small flame fig. 1).
- Remove knob "M" (fig. 14
- 14/A
) of the tap, which
is simply pressed on to its rod.
- Insert a small screwdriver "D" into hole "C" (fig. 14
- 14/A
) and turn the throttle screw to the right or
left until the burner flame has been adequately
regulated to the "Reduced rate" position.
Check that the flame does not go out when the knob is
sharply switched from the "Full on" to the "Reduced
rate" position.
It is understood that only burners operating with
G20 gas should be subjected to the above
mentioned adjustments. The screw must be fully
locked when the burners operate with G30 or G31
(turn clockwise).