11
CONVERSIONS
BURNER ARRANGEMENT ON THE HOT PLATE
12) REPLACING THE INJECTORS
The burners can be adapted to different types of gas by
installing injectors suited to the type of gas required. To do
this, first remove the burner tops using a wrench "B". Now
unscrew injector "A" (see fig. 14) and fit a injector
corresponding to the type of gas required.
It is advisable to tighten the injector in place.
After the injectors have been replaced, the burners
must be regulated as explained in paragraphs 11. The
technician must reset any seals on the regulating or
pre-regulating devices and affix the label
corresponding to the new gas regulation on the
appliance instead of the already existing one. This label
is supplied in the packet containing the spare injectors.
The envelope with the injectors and the labels can be
included in the kit, or at disposal to the authorized
customer Service Centre.
For the sake of convenience, the nominal rate chart also lists
the heat inputs of the burners, the diameter of the injectors
and the working pressures of the various types of gas.
VARY MARKETS
G30 - LPG 28 - 30 204 83 800 2800 45
2 RAPID G31 - LPG 37 200 83 800 2800 45
G20 - NATURAL 20 267 117 S 800 2800 Adj.
G30 - LPG 28 - 30 225 90 1400 3100 62
1
ULTRA RAPID
G31 - LPG 37 222 90 1400 3100 62
G20 - NATURAL 20 295 121 Y 1400 3100 Adj.
G30 - LPG 28 - 30 127 65 500 1750 35
3 SEMIRAPID G31 - LPG 37 125 65 500 1750 35
G20 - NATURAL 20 167 97 Z 500 1750 Adj.
G30 - LPG 28 - 30 73 50 400 1000 30
4 AUXILIARY G31 - LPG 37 71 50 400 1000 30
G20 - NATURAL 20 95 72 X 400 1000 Adj.
BURNERS
N° DESCRIPTION
GAS
NORMAL
PRESSURE
NORMAL
RATE
INJECTOR
DIAMETER
NOMINAL
HEAT INPUT (W)
mbar g/h l/h 1/100 mm Min. Max. 1/100 mm
BY PASS
FIG. 14