9
ADJUSTMENTS
Always disconnect the appliance from the
electricity main before making any adjustments.
All seals must be replaced by the technician at
the end of any adjustments or regulations.
Our burners do not require primary air
adjustment.
9) TAPS
"Reduced rate" adjustment
- Switch on the burner and turn the relative knob to
the "Reduced rate" position (small flame fig.12).
- Remove knob "M" (fig. 12) of the tap, which is
simply pressed on to its rod.
- Insert a small screwdriver "D" into hole "C" (fig. 12)
and turn the throttle screw to the right or left until
the burner flame has been adequately regulated to
the "Reduced rate" position.
Check that the flame does not go out when the
knob is sharply switched from the "Full on" to the
"Reduced rate" position.
It is understood that only burners operating
with G20 gas should be subjected to the above
mentioned adjustments. The screw must be
fully locked when the burners operate with G30
or G31 (turn clockwise).
FIG. 12