Vertical steam ironing
• Set the iron temperature control slide and the steam output control dial (located on the
control panel) to the MAX position.
• Hang the garment on a coat hanger and hold the fabric slightly taut with one hand.
As steam is very hot : never attempt to remove creases from a garment while it is being
worn, always hang garments on a coat hanger.
• Holding the iron in a vertical position, tilted slightly forwards, press repeatedly on the steam
c
ontrol button (underneath the iron handle) moving the iron from top to bottom – fig.9.
Refilling the water tank
• When the red "water tank empty" light starts flashing, it means that you have no more steam.fig.11.
1.Remove the water tank by pulling on the handle (at the front of the generator) and fill it, taking
care not to exceed the maximum level.
2. Slide the tank back into its housing until its clicks into place.
3. Press the “restart” button on the control panel – fig.12. to continue ironing. When the green light
stops flashing, the steam is ready.
TURBO Function (according to model)
• Press the Turbo control 2 or 3 times when you need extra steam:
- for ironing thicker fabrics,
- for getting rid of creases,
- for powerful vertical steaming.
Use the Turbo function with care as its exceptional steam power can cause burns.
Catalysis Autoclean Soleplate (according to model)
• The iron of your steam generator comes with a self-cleaning soleplate which functions by catalysis.
• Its unique coating makes it possible to eliminate all the impurities arising from normal usage.
• We recommend you always place your iron on its base or on the iron rest plate in order to protect its self-cleaning
coating.
Maintenance and cleaning
Cleaning your generator
• Do not use detergent or descaling products for cleaning the soleplate base-unit.
• Never hold the iron or the base unit under the tap.
• Cleaning the soleplate (depending on model): The iron of your steam generator comes with a
self-cleaning soleplate which functions by catalysis. Its unique coating actively allows it to
eliminate all the impurities which are generated every day when the appliance is in normal use.
Nevertheless, using your iron at an unsuitable temperature can leave marks which will need to
be cleaned manually. In this case we advise you to use a soft damp cloth on the soleplate
whilst it is still warm so as not to damage the coating.
• Clean the plastic parts of the appliance occasionally with a soft cloth.
Descaling your generator easily - Fig. A
For longer generator life, and to avoid scale emissions, your generator is
equipped with a built-in anti-scale valve. This valve, located in the tank,
automatically removes the scale that forms inside. Operation:
• An orange “anti-scale” light located on the control panel starts blinking to
tell you that the anti-scale valve needs rinsing - fig.14
Caution: this operation must not be performed until the generator has been unplugged for at least two
hours and has completely cooled down. When performing this operation, the generator should be placed
near a sink as water may flow out of the tank when it is opened.
• Once the generator has cooled down completely, remove the anti-scale valve cap.
• Unscrew the anti-scale valve and remove it from the housing; it contains the scale that has built up in the tank.
• To clean the valve properly, just rinse it under running water to remove the scale it contains.
• Put the valve back into its housing and screw it in completely to keep it watertight .
• Put the cap back on.
• In addition to this regular maintenance, we recommend complete rinsing of the tank every six months or after
every 25 uses. To do this:
• Check that the steam generator is cold and has been unplugged for more than 2 hours.
• Place the steam generator on the edge of the sink and put the iron standing upright alongside it.
78
Recommendations: for
fabrics other than linen or
cotton, hold the iron a
few centimetres from the
garment to avoid burning
the fabric.
Cleaning tip: For
easier, non-corrosive
cleaning of your
iron’s soleplate, use a
damp sponge on the
soleplate while it is
still warm.
Do not use any descaling substances (vinegar,
industrial descaling products, etc.) when
rinsing the anti-scale valve : they could
damage it. Before descaling or cleaning your
generator, you must let it cool down for at
least 2 hours to avoid any risk of burns.
1800129556 GV83XX-GV84XX E0 A11_110x154 25/03/13 14:43 Page78
78


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Tefal GV 8460 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Tefal GV 8460 in the language / languages: All languages as an attachment in your email.

The manual is 5,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Tefal GV 8460

Tefal GV 8460 User Manual - Dutch - 10 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info