NEW BATTERY PROGRAM (1 HOUR):
PRE-QUALIFICATION TEST: RED LED #9 flashing
The battery voltage is below 12V which is not expected for a new dry charged battery recently filled with acid according to the
manufacturers instructions and the acid was allowed to settle for at least 60 minutes before connection to the charger; the
battery may have fatal damage such as a shorted cell. DO NOT CHARGE OR USE THE BATTERY.
For a new factory activated AGM or GEL that may have lost charge during extended storage, select the 2A or 4A program
according to the battery parameters and try again.
RECOVERY / DESULPHATE: LED #5
This mode is disabled for NEW batteries.
CHARGE: LED #6
BULK charge - LED #6 steady on: The ampmatic™ charge current monitoring and control mode automatically determines the
most efficient rate of charge current for the connected battery, according to its state of charge, state of health, and electrical
storage capacity. The delivered current may be anywhere from 0.4A to 4A.
FINAL charge - LED #6 flashing: The FINAL CHARGE mode starts when the voltage has reached 14.3V for the first time
during BULK CHARGE stage.
Pulsed equalization step: If the battery has accepted as much charge as its basic condition allows the ampmatic™ current
control circuit now delivers pulses of current for 10 minutes so as to cause the battery voltage to vary between 13.7V and 14.3V,
to equalise the individual cells within the battery.
Verification step: The battery's charge level is verified. If the battery requires further charging the program will revert to pulsed
equalization.
NOTE: For safety reasons there is an overall charge time limit of 1 hour.
VOLTAGE RETENTION TEST: LED #7 flashing
Delivery of current to the battery is interrupted for 10 minutes to allow the program to determine the battery's ability to retain
charge. A small load is applied to remove surface charge and improve test result accuracy.For batteries with a good state of
health LED #7 (green) should continue to flash for the full period.
Consult the “EARLY WARNING OF BATTERY PROBLEMS” table on page 2 for LED indications other than LED #7 (green).
A significant problem exists if the battery is unable to retain sufficient charge during the 12 hour test period. Read the section
NOTES ON TEST RESULTS on reasons for poor test results or how to test a battery that returns a good result but cannot deliver
sufficient power once it is returned to service.
MAINTENANCE CHARGE: LED #7 /8 / 9 steady on
The circuit offers current to the battery within a safe 13.6V voltage limit whilst the result of the voltage retention test is displayed.
Consult the “EARLY WARNING OF BATTERY PROBLEMS” table on page 2 for LED indications other than LED #7 (green).
A more detailed description of the automatic maintenance cycle for long term battery storage can be found under the section
AUTOMATIC BATTERY MAINTENANCE.
2A / 4A PROGRAM for USED / NEGLECTED batteries:
(or NEW batteries that may have been stored for extensive periods following initial activation):
VERY FLAT NEGLECTED BATTERIES: If the battery is deeply discharged (and possibly sulfated), remove from the
vehicle or equipment and inspect the battery before connecting the charger for a recovery attempt.
Pay particularly close attention to the following A battery left deep-discharged for an extended period may develop permanent
damage in one or more cells. Such batteries may heat up excessively during high current charging.
Monitor the battery temperature during the first hour, then hourly there-after. Check for unusual signs, such as bubbling or leaking
electrolyte, heightened activity in one cell compared to others, or hissing sounds. If at any time the battery is uncomfortably hot to
touch or you notice any unusual signs, DISCONNECT THE CHARGER IMMEDIATELY.
NOTE: The charger’s TURBO recovery mode cannot engage if it senses that the battery is still connected to a circuit which
effectively offers a lower electrical resistance than the battery on its own. However, if the deep-discharged battery is not removed
for recovery, neither battery nor vehicle or equipment electronics will be damaged.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Tecmate Optimate Pro 4 - TS52 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Tecmate Optimate Pro 4 - TS52 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 1,91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info