can be seen from the outside, examine the battery carefully to try to determine if any cells seem different to the others
(for example, with white matter between the plates, plates touching). If mechanical defects are apparent do not
attempt to charge the battery, have the battery professionally assessed.
5. , before connecting the charger read the battery manufacturer’s safety and operational
instructions carefully. If applicable, carefully and exactly follow acid filling instructions.


 

A battery left deep-discharged for an extended period may develop permanent damage in one or more cells.
Such batteries may heat up excessively during high current charging.
Monitor the battery temperature during the first hour, then hourly there-after. Check for unusual signs, such as bubbling or
leaking electrolyte, heightened activity in one cell compared to others, or hissing sounds. If at any time the battery is
uncomfortably hot to touch or you notice any unusual signs, DISCONNECT THE CHARGER IMMEDIATELY.
 The power converter
switches to ECO mode when the charger is not connected to a battery resulting in a very low power draw of less than 0,5W,
equivalent to power consumption of 0,012 kWh per day. When a battery is connected to the charger power consumption
depends on the current demand of the battery and its connected vehicle / electronic circuitry. After the battery has been
charged and the charger is in long term maintenance charge mode (to keep the battery at 100% charge) the total power
consumption is estimated to be 0,060 kWh or less per day.


Model: TM420
INPUT/SECTEUR/RED/NETZ/ALIM./
INGANG/INSPÄNNING:
100-240V 50-60Hz
0,23A@100Vac / 0,15A@240Vac
OUTPUT/SORTIE/SALIDA/LEISTUNG/
USCITA/UITGANG/UTSPÄNNING/
SAIDA:
12V 0,8A
3 - 96Ah
LED #4 - MAINTAIN
LED #3 - CHARGE
LED #1 - AC POWER (100-240V)
LED #2 - Reverse polarity
1. 
2. 

 CHARGE: The BULK CHARGE stage ( LED #3) delivers a constant current of about 0,8 Amps maximum into the
battery, up to a voltage of 14,2 -14,5V.
 VERIFICATION: LED #4 turns on while the circuit verifies battery charge level.
If the battery requires further charging the programme reverts to BULK CHARGE (LED #3) for brief periods,
delivering a variable current pulse to the battery. These reversions may occur as many times as is necessary to
reduce the battery’s current demand below 200mA at 13,6V (which is consistent with a battery that has accepted
as much charge as its basic condition allows). (see expected Charging time below.
If LED#3 and #4 alternates every 2-3 seconds the battery may be in a sulphated condition and unable to initially
accept charge current. Monitor for 2 hours whilst the charger attempts to deliver charge to the battery. A lightly
sulphated battery may recover and accept full charge current as confirmed by a steady LED#3. If the condition
remains unchanged the battery may be in an advanced state of sulphation and that despite recovery attempts the
battery was irrecoverable. This may be due to a defect in the battery itself, such as a short-circuited cell or total
sulphation, or, in the case of a battery still connected to the vehicle’s wiring system, it may be signalling a loss of
current through deteriorated wiring or a degraded switch or contact, or in-circuit current-consuming accessories.
A sudden load such as the headlights being switched on while the charger is connected can also cause the
battery voltage to dip significantly. Always remove the battery from the vehicle, reconnect the OptiMate
and
allow it to proceed through its programme once more.
www.optimate1.com for the appropriate OptiMate model able to recover batteries from advanced sulphation.
6


Need help? Post your question in this forum.

Forumrules
1

Forum

tecmate-optimate-2---tm240

Reset search

  • volevo sapere se optimate 2 è in grado di ricaricare una batteria auto da 82 Ah e se in quanto tempo. Submitted on 2-10-2020 at 19:38

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Tecmate Optimate 2 - TM240 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Tecmate Optimate 2 - TM240 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Swedish, Spanish as an attachment in your email.

The manual is 2,35 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info