Note:
To activate/modify the second personal code you shall always program the first one again.
5. RESETTING CODES
Is possible cancel the personal codes pressing the “button PROGRAMMING” and the “ON” button for 5 sec.
The first code goes on 111111 and the second code will be deactivated.
Note:
If errors have been made while setting your new code, this will be indicated by the red “ERRORLED lighting up and a beep.
Proceed in that case, a new and correct their own personal code by repeating the steps under item 4.
In memory was previously the code set to error (a new safe “111111”).
Before closing the safe, it is recommended to carry out a door open, some evidence of initiation using its personal
code.
6. OPENING THE SAFE USING YOUR PERSONAL CODE
Press “ON”
Enter your personal code set earlier and press “ENTER”. The green “OK” LED lights up for five seconds. Within this time,
turn the knob clockwise and open the door.
7. SIGNAL INDICATING THAT INTERNAL BATTERIES ARE GOING FLAT
When the internal batteries begins to go flat, this is indicated at the end of the opening procedure, by the red “BATTERY LED
lighting up and a low beep tone. At this point, it will still be possible to open the safe a number of times. Replace the internal
ALKALINE batteries.
8. EMERGENCY OPENING WITH INTERNAL BATTERIES FLAT
If the failing batteries goes completely flat, as soon as the keyboard is pressed, to proceed with opening the safe:
It is necessary to use a new 9V LR61 alkaline battery externally (see Pic. 2);
Press the 9V battery contacts firmly on the corresponding contacts on the keyboards, ensuring that they are positioned
correctly (the “-“ of the battery touching the bigger contact and the “+” of the battery touching the small contact);
Press “ON” and enter your personal code, followed by the key “ENTER”;
Turn the knob clockwise to open the door.
9. ONLY VERSIONS WITH EMERGENCY KEY:
OPENING WITH EMERGENCY KEY
Remove the adhesive label marked with the letter “E(Pic.3);
Insert the key and open the lock up to the stop point, turn the knob clockwise and open the door;
By holding the door open, turn the knob until the emergence of full bolts and remove the key after rotated counter clockwise.
To replace the label E;
Note: If the opening with key emergency is necessary for the oversight of their own personal code, you must store a new code
following the instructions at point 4.
IMPORTANT !
Should replace the batteries once a year
Even new batteries may be defective or short-term. Therefore, in the event of a malfunction of the electronic system,
ensuring, first of all, to replace the internal batteries.
The manufacturer assumes no liability for non-compliance with the instructions or improper use of safe (penalty decay of
the guarantee).
CONTACTS
FOR
EXTERNAL
BATTERY
Pic. 2
STICKERS
KEY FOR
EMERGENCY
Pic. 3
Detail of the sliding closing to
protect the PROGRAMMING key
BATTERY CASE
Pic. 1
SCREW TO BE
REMOVED
In the smallest models the
PROGRAMMING key is
on the top.
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Technomax DPE vanaf 2009 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Technomax DPE vanaf 2009 in the language / languages: English as an attachment in your email.

The manual is 0,26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Technomax DPE vanaf 2009

Technomax DPE vanaf 2009 User Manual - Dutch - 2 pages

Technomax DPE vanaf 2009 User Manual - French - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info