RUNRACE : Service & Maintenance Manual - rev. 2.0
Page 10.5
4. Check the state of wear of the motor roller. Replace if it shows evident signs of wear.
10.3.6. CHECKING THE WEAR OF THE REAR ROLLER
1. Turn off the machine by placing the switch in the 0 position (OFF).
2. Unplug the mains lead from the wall outlet.
3. Check the state of wear of the rear roller. Replace if it shows evident signs of wear.
10.3.7. CHECKING THE WEAR OF THE RUBBER HANDLEBAR COVERS
1. Check the state of wear of the rubber covering on the 2 side handlebars and on the center
handlebar. Replace if they show evident signs of wear.
10.3.8. CHECKING THE TREAD BELT MOTOR DRIVE-BELT
1. Turn off the machine by placing the switch in the 0 position (OFF).
2. Unplug the mains lead from the wall outlet.
3. Open the motor guard.
4. Check the state of wear of the tread motor drive-belt, turning it by hand using the motor
flywheel. Replace if it shows evident signs of wear.
5. Check the tension of the motor drive-belt. Adjust the tension if necessary.
10.3.9. CHECKING THE UP-DOWN MOTOR DRIVE-BELT
1. With the machine powered-up, raise it to its maximum incline (25%).
2. Turn off the machine by placing the switch in the 0 position (OFF).
3. Unplug the mains lead from the wall outlet.
4. Remove the guard plate of the up-down motor drive-belt.
5. Check the state of wear of the up-down motor drive-belt. Replace if it shows evident signs of
wear.
6. Check the tension of the up-down motor drive-belt. Adjust the tension if necessary.
10.3.10. CHECKING THE SHOCK ABSORBERS
1. Only after having worked on the tread belt and/or running track, check the condition of the
shock absorbers on either side of the running track. Replace if they are cracked or show signs of
breakage.
10.3.11. CHECKING THE SPEED CALIBRATION
1. Open the motor guard.
2. Check that when the machine runs at a speed of 12.6 km/h the inverter displays a working
frequency of 50 Hz.
WARNING: this must be done with the machine opened and powered up.
10.3.12. CHECKING THE OPERATION OF THE CARDIO RECEIVER
1. Using a separate heart rate monitor, put on the transmitter strap and check that the machine and
the separate monitor both measure the same heart rate, and that when the strap is disconnected
the machine does not receive any signal.
2. Using a heart rate frequency simulator, check that the machine detects the variations in the heart
rate.