536099
182
Zoom out
Zoom in
Previous page
1/200
Next page
Part XIII MIDI
182
QQTG0692
MIDI
Common Setting
Set the functions which are common to all parts.
1.
On the MIDI MENU display, select COMMON
SETTING.
The display looks similar to the following.
2.
Use and buttons to select the item.
NOTE ONLY:
Of the performance data, specify whether or
not only note data is exchanged.
PROGRAM CHANGE TO P. MEM:
Enable or disable the exchange of program
change numbers for the RIGHT 1 part by
operation of the PANEL MEMORY buttons.
For this setting, the PANEL MEMORY 1 to 8
program change numbers correspond to the
bank numbers as follows:
BANK A = 0 to 7
BANK B = 8 to 15 ...
INTRO, FILL-IN, ENDING:
Enable or disable the exchange of intro, fill-in
and ending data.
APC CONTROL:
Enable the exchange of data for the on/off sta-
tus of the AUTO PLAY CHORD’s BASIC,
ADVANCED and PIANIST modes.
FADE IN/OUT:
Specify whether or not FADE IN/OUT data is
exchanged.
PROGRAM CHANGE MODE
NX SOUND:
Program change numbers are standardized
among NX SOUND Technics models which
are set to this mode. The program change
number assigned to a given sound on one
model is assigned to the same sound on all
models which are set to the same mode.
PREVIOUS TECH:
Program change numbers are standardized
among non-NX SOUND Technics models
which are set to this mode. The program
change number assigned to a given sound
on one model is assigned to the same
sound on all models which are set to the
same mode.
MAP R:
GS basic sounds are transmitted and
received as GS program change numbers.
MAP Y:
XG basic sounds are transmitted and
received as XG program change numbers.
GS is a trademark of Roland Corporation. XG is a
trademark of Yamaha Corporation.
DRUMS TYPE
NX SOUND:
Keyboard percussion instrument sounds
correspond to the same key note numbers
for connected NX SOUND Technics models
that are set to this type.
PREVIOUS TECH:
Keyboard percussion instrument sounds
correspond to the same key note numbers
for connected non-NX SOUND Technics
models that are set to this type.
SONG SELECT
ON:
Song number data can be exchanged.
OFF:
Song number data cannot be exchanged.
PREVIOUS MODEL MODE
ON:
INTRO, FILL IN, ENDING and APC CON-
TROL, FADE IN/OUT data are converted to
CONTROL CHANGE data for previous
models and then transmitted.
OFF:
The above settings are not converted.
“Previous models” include all Technics instrument
models except for:
KN7000/6500/6000
PR604/804/603/703/903/1000
3.
Use
and
buttons to change the setting.
4.
Repeat steps 2 and 3 for the other settings as
desired.
18_Part XIII.fm 182 ページ 2003年3月6日 木曜日 午後1時36分
182


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Technics SX-KN2400 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Technics SX-KN2400 in the language / languages: English as an attachment in your email.

The manual is 7,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info