658458
14
Zoom out
Zoom in
Previous page
1/33
Next page
12
PRESET HANDLING
Parameter types
The VoiceWorks has over 100 useful
parameters and a user interface that lets you
view and edit efficiently. Some parameters are
preset based and some are setup based.
Preset parameters are all the parameters
found under the eight Voices & Effects keys.
Each preset has its own set of these
parameters.
Setup parameters are global and do not
change when a different preset is recalled.
Setup parameters are all the parameters found
under the setup menu including Lead input
level and pan, Compression/Gate, and EQ
parameters among many others. If you
change your microphone (or singer!) the
EQ/Compression settings need to only be
adjusted once in the setup menu. If you wish
to backup your setup settings, the VoiceWorks
is able to MIDI dump setup parameters to
sysex for later retrieval.
Preset Types
It’s important to understand the concept of the
current preset versus stored presets.
The current preset is the preset that is always
active in the VoiceWorks. Recalling a preset
copies preset data from one of the 100 stored
presets into the current preset. As you change
the current preset, the underlying stored
presets are not affected until you choose to
store the current preset back to a stored
preset.
When dumping and receiving presets via MIDI,
data is dumped from and received to stored
presets. The current preset remains
untouched. For example, if you are looking at
preset 5 and receive a SYSEX preset to preset
5, it will seem as if nothing has changed. The
preset you are looking at is still the current
preset. Press RECALL to copy the new data
from the stored preset 5 to the current preset.
It is possible to directly receive and dump from
the current preset. Refer to the SYSEX MIDI
documentation available on our website.
When presets are recalled or previewed, the
first line of the LCD display shows the preset
name and the second line displays the
harmony voicings.
See the INDIVIDUAL VOICE KEYS description
for more on Harmony Voicing.
After a few seconds the first line changes to
display the harmony mode, the
root/scale/chord information, or when in
Harmony Notes Mode, the currently detected
notes coming from MIDI.
All presets may be restored to their factory
default from the setup menu.
Global Effect Presets
If you select a preset for the G
LOBAL EFF
parameter in the setup menu, its effect
settings will be used regardless of the current
preset effect settings.
If you store the current preset while a Global
Effect is active, the current preset data will be
stored to the selected preset number, but any
changes to the effect data (which come from
the Global preset) will be stored to the global
preset.
RECALL
Recalling a preset means loading/activating a
stored preset. The stored preset data is
copied into the current preset.
Press RECALL to enter recall mode.
Use the DATA WHEEL to preview presets.
Blinking preset names/information indicates
a previewed preset. Previewing means that
you have not actually loaded the preset.
Press ENTER or RECALL to recall/activate
the currently previewed preset. This
transfers the stored preset to the current
preset.
14


Need help? Post your question in this forum.

Forumrules
1

Forum

tc-helicon-voiceworks

Reset search

  • my older voiceworks does not want to store the settings or have i forgot how. i do not have
    the manual can somone please refresh how..... thanks Submitted on 3-4-2022 at 18:57

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for TC Helicon Voiceworks at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of TC Helicon Voiceworks in the language / languages: English as an attachment in your email.

The manual is 1,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of TC Helicon Voiceworks

TC Helicon Voiceworks User Manual - German - 33 pages

TC Helicon Voiceworks User Manual - Dutch - 31 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info