BP Smart Battery Charger User Manual V1.1
Check the manual or manufacturer of your battery and set the dip switch 2-4 at the proper
situation according to the recommended absorption and floating voltage.
Plug in the temperature sensor to the battery charger and fasten the sensor head directly
to the battery.
To assure the right charging and avoid the chance of over¬-temp in battery, it is strongly
recommended the temperature sensor should be connected during charging.
When the charging is completed, the battery charger enters into Floating Mode, and the
"charged" light is ON.
Recharging: BP Series battery charger will begin a charging cycle 14 days after the last
cycle.
WARNING
The battery charger is designed to have no output if no battery is connected.
4.3 Simultaneously Recharging and Power Supply
It is strongly recommended to check your DC load requirement if you are connecting DC load
while charging.
WARNING
If your DC load is voltage sensitive and did not permit high input over 14.5VDC (12V
models) and 29VDC (24V models), do not connect DC load while charging if you are
charging your FREEDOM batteries.
4.4 Using A Generator as Source Power
Many generators provide output voltage that is modified sine wave (MSW) rather than the true
sine wave (TSW) that your utility provides. TBB does not permit the use of BP Series + with
modified sine wave generator due to increased heating of the charger.
TBB Power Co. Ltd. 13