727640
11
Zoom out
Zoom in
Previous page
1/28
Next page
English
Specications:
Voltage; 220-240V
Frequency: 50Hz
Dehumidifying capacity: 33.6L/j
Airow: 453m3/h4
Exhaust pipe diameter: 1.5m/150mm
Working temperature: between 7-40ºC
Timer: 24 hours
Class I
Refrigerant gaz: R410A
Product size: 47*84*37cm
Product weight: 36kg
For EU product versions and/or in case that it is requested in your country:
Anomalies and repair
- Take the appliance to an authorised technical support
service if product is damaged or other problems arise.
Do not attempt to disassemble or repair the appliance
yourself as this may be dangerous.
- If any anomaly is detected, check the following table:
Anomalies Causes Solutions
The unit does not work No power supply
Water full indicator illuminate
Timer function is active
Room temperature too low or too high
Turn on the appliance
Drain out the inner stored water
Cancel timer function
Suggesting ambient temperature between 7-40ºC
The unit does not seem to
perform
Indirect sunlight
Window or doors open
Filter is very dirty
Air inlet or air outlet is blocked
Room temperature is lower than the setting
one
Draw the curtains
Close windows and turn on another air conditioner
Clean or change the air lter
Clean out the stemming
Change the temperature setting
The unit noise is high The unit is not put on a at surface Put the unit on a at and stable surface that can
support its weight
Compressor does not work Heat exceeded protection is active Re start the unit 3 minutes later till the temperature
low down
Remote control does not
work
The distance is too far
The batteries run out
Let the remote control near the unit
Change the batteries
E1 on LCD Coil temperature is abnormal Check coil temperature sensor or relevant circuit
Contact the technical support
E2 on LCD Room temperature is abnormal Check the room temperature sensor.
Contact the technical support
E3 on LCD No refrigerant or there is very few refrigerant Check leakage, wielding, vacuum pump and contact
the technical support
P2 on LCD The water tank is full Drain out the water
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Taurus AC 350 KT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Taurus AC 350 KT in the language / languages: English, French, Portuguese, Spanish as an attachment in your email.

The manual is 2,18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info