76 TASCAM SS-CDR200/SS-R200/SS-R100
Using the RS-232C connector
Using the 9-pin, D-sub CONTROL I/O RS-232C connector,
which is compliant with RS-232C standards, you can
control the unit via this serial connection from a computer
or other external device.
Use the menu to make settings related to communication.
1 Press the MENU [JOG] button (or remote control
MENU button) to open the
MENU
screen.
2 Open the
UTILITY
menu.
3 Select
RS-232C
.
4 Press the MULTI JOG dial or , [LOCK] button (or
remote control ENTER or t button) to open the
RS-232C
setting screen.
5 Set the items on the
RS-232C
screen.
BAUD RATE
Set the baud rate (communication speed).
Options:
4800 bps
,
9600 bps
,
19200
bps (default
value),
38400 bps
PARITY BIT
Set the parity bit use.
Options:
NON
(none, default value),
EVEN
,
ODD
STOP BIT
Set the stop bit.
Options:
1
(default value),
2
DATA LENGTH
Set the data length.
Options:
7
,
8
(default value)
6 After setting each item, press the HOME/DISPLAY
button (or remote control HOME/DISP button) to
return to the Home Screen.
NOTE
RS-232C settings are retained even after the power is
turned OFF.
For details on the unit’s RS-232C command protocol,
please contact TASCAM customer support.
Using the parallel connector
Using the CONTROL I/O PARALLEL connector, you can
control this unit through serial connection with a TASCAM
RC-SS20 or other external controller. The pin assignments
are as follows.
Pin Function IN/OUT
1 GND
2 PLAY/Flash 1 In
3 STOP/Flash 2 In
4 RECORD/Flash 3 In
5
/ (Next)/Flash 4
In
6
. (Previous)/Flash 5
In
7 Flash Load In
8 Fader Start In
9 Flash Tally Out
10 Ready Tally Out
11 Record Tally Out
12 Stop Tally Out
13 Play Tally Out
14 Remote Select*
2
In
15 Ready/Flash 6 In
16 Call/Flash 7 In
17 Auto Cue/Flash 8 In
18 Auto Ready/Flash 9 In
19 Pitch/Flash 10 In
20 Flash Page*
3
In
21 EOM Tally Out
22 Device Select Tally 1*
4
Out
23
24 Device Select Tally 2*
4
Out
25 +5V*
1
In: Active low external command reception (Functions
when connected to GND for at least 30 msec usually
and at least 1 sec when recording an MP3 file)
Out: Signal for transport status display by open drain
(maximum voltage 50 V, maximum current 50 mA)
*1 Maximum supplied current 100 mA.
*2 Pin 14 (Remote Select)
When set to high, input pins with two functions shown
above with a “/” (pins 2–6 and 15–19) use the first
function, and can be used for ordinary parallel control.
When set to low, these input pins function as flash
start keys.
*3 Pin 20 (Flash Page)
When pin 14 (Remote Select) is set to low, the high/low
setting of pin 20 determines the track assignments.
#14 #20 Flash start tracks
Low High 1–10
Low Low 11–20
14 − Using control I/O (SS-CDR200/SS-R200 only)
76


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Tascam SS-CDR100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Tascam SS-CDR100 in the language / languages: English as an attachment in your email.

The manual is 3,18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info