PORTASTUDIO MF-P01
15
Tracing faults in a recording setup is often a mixture
of logical deduction and patience. Very often, the
problem is caused by something simple; a cable
which hasn’t been plugged in properly, or a faulty
cable. If you discover a faulty cable, replace it with a
new one - it’s not worth hanging onto bad cables!
The MF-P01’s POWER light does not come on.
Is the PS-P2 adaptor plugged into the power supply?
Is the PS-P2 adaptor plugged into the MF-P01?
Is the POWER switch on the MF-P01 set to ON?
The tape does not move when the PLAY button is
pressed.
Is the tape properly inserted in the MF-P01?
Is the tape at the end of the tape?
Some tracks have been recorded on the tape, but
nothing can be heard when playing back.
If you’ve just put in a tape you recorded in another
session, make sure that it’s the right way round.
Make sure the LEVEL and MASTER controls are set
appropriately (not to "0").
If you can hear something through the headphones
but cannot from the speakers, check the LINE OUT
connections and make sure the amplifier is set to the
correct input source.
Nothing appears on the meter indicators when a
source is played.
Is the source (microphone, guitar, etc.) switched on
and volume control turned up? If it uses batteries,
does it need new batteries?
Is the INPUT LEVEL control of the channel set
appropriately (not to "0")?
Cannot press the RECORD key.
Is the tape properly inserted in the MF-P01?
Is the tape record-protected?
The RECORD key is pressed, the tape moves, but
nothing is recorded, or the level is very low.
Is one of the REC FUNCTION switches depressed?
Check the LEVEL control for the track.
Is the INPUT LEVEL control set correctly?
Is the recording level is too low or too high?
Tape sounds are muffled on playback.
The heads are dirty. Clean them (see "Cleaning the
heads").
The mixdown signal is noisy or distorted.
Is the recording level is too low?
Is the PHONES plug is connected during mixdown?
Track format:
4 tracks, 4 channels
Head configuration:
1 x 4-track record/replay head (Permalloy)
1 x 4-track erase head (ferrite)
Motor type:
1 x DC motor (capstan and reel motor)
Tape speed:
1 7/8 in./sec (4.76 cm/sec)
Wow and flutter:
0.25%
Fast wind time:
Approx 120 seconds (C-60 tape)
Power requirements:
USA/CANADA: 120 V AC, 60 Hz
U.K./EUROPE: 230 V AC, 50 Hz
AUSTRALIA: 240 V AC, 50 Hz
Power consumption:
7 W, via the supplied PS-P2 AC adaptor
Physical dimensions (w x h x d):
295 x 70 x 205 (mm), 12.0 x 2.8 x 8.1 (in.),
maximum height (including controls)
81 (mm), 3.2(in)
Weight (main unit):
1.1 kg (2.4 lb)
MIC/LINE input (1/4" phone jack)
Input level:
–50 dBV or higher
Input impedance:
50 k
LINE OUT (2 x RCA jacks)
Output level:
–10 dBV
Output impedance:
10 k
Specifications
Troubleshooting
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Tascam MF-P01 Portastudio at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Tascam MF-P01 Portastudio in the language / languages: English as an attachment in your email.

The manual is 0,57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info