26 TASCAM CG-2000
9 – Other functions
Alarm output
This unit has a function that allows it to output an alarm through
a dedicated connector when trouble occurs. To use this function,
just connect the
ALARM OUTPUTS
connectors as required.
ALARM OUTPUTS connectors
Pin Details
1 +5V
2 Outputs when there is an unchecked error log
3 GND
4 +5V
5 Outputs while an error is occurring.
6 GND
Power redundancy function
This unit has two power supply circuits, and supports redun-
dancy to prevent problems related to the power supply.
By default, the power redundancy function is off. If you want
to use it, follow the procedures below to turn this function on
and connect two different power supplies to the two power
connectors.
If the power redundancy function is on when only one of
the power circuits is connected, the unit will determine that
one power supply has been interrupted and the POWER
REDUNDANT indicator on its front will blink. In this case, turn
the power redundancy function off.
Setting the power redundancy function
You can turn the power redundancy function on or off.
Make this setting from the
UTILITY 1
page.
1. Press the MENU button repeatedly to open the
UTILITY
1
menu page, and turn the MULTI JOG dial to select the
POWER RED.
item.
2. Press the MULTI JOG dial to open the
POWER
REDUNDANT
screen.
3. Turn the MULTI JOG dial to turn the power redundancy
function on or off.
Options: OFF (default), ON
4. Press the MULTI JOG dial to confirm the selection and return
to the menu.
NOTE
Press the EXIT/CANCEL button while making a setting to
cancel the change and return to the menu screen.
Setting the termination for reference
input connectors
Set the termination for each input connector according to the
wiring.
Make these settings on the
TERMINATION
page.
1. Press the MENU button repeatedly to open the
TERMI-
NATION
menu page, and turn the MULTI JOG dial to select
the input connector for which you want to set the termi-
nation.
VIDEO A selected
2. Press the MULTI JOG dial to open the
TERMINATION
XXX
screen (“ XXX” is the name of the input connector).
TERMINATION VIDEO A
screen open
3. Turn the MULTI JOG dial to set the termination for the input
connector.
Options
Video clock input connector: 75ohm (default), OPEN
Word clock input connector: 75ohm (default), 50ohm,
OPEN
GPS signal input connector: 50ohm (default), OPEN
4. Press the MULTI JOG dial to confirm the selection and return
to the menu.
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Tascam CG-2000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Tascam CG-2000 in the language / languages: English as an attachment in your email.

The manual is 0,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info