Window Types and Requirements
Note:
·The description for below installation is for the standard window. If its other types of
window, you may need to adjust the window.
·If you need to install the air conditioner at the small window, you may not need to use
the accordion panel sub-assy. Please refer to requirement of window size for details.
·All parts used for supporting air conditioner should be fixed at solid wooden strap,
brick or metal.
·Socket must be installed at the position where the power cord is available.
Standard window
25“-36"
13.5" Min.
Weather-proof Type Window
The height of window frame is higher than windowsill for some weather-proof type window,
which will affect the installation of air conditioner. In this case, before installing the air
conditioner, add wooden strap on the windowsill, and fix the wooden strap at the windowsill.
Specification of Wooden Strap
Width: about 2”
Length: same to the inner frame size of window
Height: Put the wooden strap on the windowsill, top part of wooden strap and window frame
should be at the same horizontal level, or higher than the top part of window frame for
about 1/4"-1/2"
1/4"-1/2"
Wooden Strap
Windowsill
Inner Wall Side
Weather-proof
Window Frame or
Plastic Window Frame
Requirements before Installation
WARNING
·Observe all governing codes and ordinances.
·Do not use damaged or non-standard power cord.
·Be caution during installation and maintenance. Prohibit incorrect operation to prevent
electric shock, casualty and other accidents.
Selection of Installation Location
Basic requirement
Installing the unit in the following places may cause malfunction. If it is unavoidable, please
consult the local dealer:
1. The place with strong heat sources, vapors, flammable or explosive gas, or volatile objects
spread in the air.
2. The place with high-frequency devices (such as welding machine, medical equipment).
3. The place near coast area.
4. The place with oil or fumes in the air.
5. The place with sulfureted gas.
6. Other places with special circumstances.
7. Its not allowed to be installed on the unstable or motive base structure (such as truck) or in the
corrosive environment (such as chemical factory).
Requirement of complete unit
1. There should be no obstruction near air inlet and air outlet.
2. Select a location where the condensation water can be dispersed easily and won't affect
other people.
3. The location should be able to withstand the weight of the unit and won't increase noise
and vibration.
4. Select a location where the noise and outflow air emitted by the outdoor unit will not
affect neighborhood.
5. The location should be able to withstand the weight of unit.
6. Select a location which is out of reach for children and far away from animals or plants. If it is
unavoidable, please add fence for safety purpose.
7. Please try your best to keep far away from fluorescent lamp.
01 03 05 07 09 11 13 15
17 19 21 23 25 27
02 04 06 08 10 12 14 16
18 20 22 24 26 28
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for TaoTronics TT-AC003 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of TaoTronics TT-AC003 in the language / languages: English as an attachment in your email.

The manual is 3.75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info