GBGB
Safety Notes (continued)
4
For the SC-240MA; Ensure you use the original AC adapter. Using an AC adapter (model A30930G)
other than the original one may cause malfunction.
Do not insert or remove the plug by the cable.
Do not take measurements while using transmitters, such as mobile phones, which may
affect readings.
<Usage Conditions>
Temperature Range for Use : 5°C - 35°C
Relative Humidity : 30% - 80% (without condensation)
<Storage Conditions>
Temperature Range of Environment: -10°C - 50°C
Range of Relative Humidity : 10% - 90% (without condensation)
To avoid malfunctions, avoid storing the equipment where there is direct sunlight, significant
temperature changes, the risk of dampness, a large amount of dust, in the vicinity of fires, or
where there is the risk of receiving vibrations or shocks.
<Power Source>
Voltage Range
Frequency Range
Electric Current Range
230VAC
50Hz
65mA
This equipment sends out a very weak electric current to measure impedance (electrical
resistance) of the body. Therefore, in principle, users need to use this equipment with bare feet.
Moreover, since impedance fluctuates in accordance with the distribution of body fluid, please
observe the following instructions for accurate measurement.
To prevent a possible discrepancy in measured values, avoid taking measurements after vigorous
exercise until sufficiently rested.
To prevent inaccurately low body fat percentage measurements and other measurement errors,
always hold both arms straight down when taking measurements.
•As changes in body water and body temperature can have a major impact on measurements,
measurements should be made every day at the same time under similar conditions (always
urinating before taking measurements, etc.) to get a more accurate picture of the measurements
over time.
Also, make sure the soles of feet are free of excess dirt, as this may also act as a barrier to the mild
current.
False results may be reported after excessive food / fluid intake, or after periods of intense exercise.
This equipment is designed for the majority of the population leading healthy lives with a regular
lifestyle. For people suffering from sickness, or whose lifestyle is very different from the norm, it is
recommended that the data from this product should not be used as an absolute value, but rather
as a reference to observe the rate change.
If there are calluses on the soles of the feet, or an individual is wearing thin nylons, accurate
measurement may still be possible. Place 0.5ml of water in the centre of each electrode. This will act
as a conductant, and may allow the current to pass freely through a thin barrier.
Measurement is sometimes impossible on a surface that is strongly vibrating. In this case, please
move the equipment onto a surface with little vibration.
Since this equipment is accurately manufactured and adjusted, please observe the following
instructions.
Users must not disassemble or adjust this equipment. This should be done by trained maintenance
agents or certification offices designated under the NAWI directive.
Never disassemble the equipment as this may cause malfunction. Users must not disassemble or
adjust this equipment. Please inspect the equipment in accordance with the regulations in your
country.
Unplug the unit from the wall outlet when it will not be in use for long periods of time.
Keep the electrodes clean by wiping them with disinfectant.
Do not drop the unit, and avoid locations with constant vibration.
Do not put this equipment in direct sunlight, close to heaters or near direct draughts from air
conditioners.
When transferred to any location where there is a difference of more than 20˚C, wait 2 hours before
using.
•When disposing of this unit, please do so in accordance with the prevailing regulations in each
country.
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Tanita SC-240MA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Tanita SC-240MA in the language / languages: English as an attachment in your email.

The manual is 1,86 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Tanita SC-240MA

Tanita SC-240MA User Manual - German - 24 pages

Tanita SC-240MA User Manual - French - 24 pages

Tanita SC-240MA User Manual - Spanish - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info