TROUBLE SHOOTING
• The power doesn’t turn on.
Insert 2 new size AA (“R6” or “15c”) batteries. Be sure that the polarity of the batteries is set
properly.
• “Err6” or “Err7” appears on the display.
The scale needs to be repaired. Please contact your retailer.
• “Err1” or “Err8” appears on the display.
Place a container or item(s) after 0 g/0.00 oz is displayed.
• The scale does not set to micro mode.
• M mark disappears while operating.
Minimum display is 1 g/0.05 oz.when the total weight on the tray is 1500 g/52.9 oz or more.
Press
again after removing the weight.
Although weight is 300 g/10.58 oz or less in the micro mode, 0.1 g/0.01 oz unit is not displayed.
Was the display set to indicate 0 g/0.00 oz once during the additional measurement (tare
weighing)?
Once weight total on the tray exceeds 300 g/10.58 oz, the display indicates in 1 g/0.05 oz units
even if 0 g/0.00 oz is displayed using
. Likewise, when the weight exceeds 1500 g/52.9 oz,
the display indicates in 1 g/0.05 oz units.
In the micro mode, once weight total becomes 300 g/10.58 oz or more, the display indicates in
0.5 g/0.02 oz or 1 g/0.05 oz even though the weight is removed. Remove all weight from the
tray, press
to return display to 0.0 g/0.00 oz, and measure the weight in accordance with
the minimum display unit that corresponds to the total weight on the scale.
SPECIFICATION
Capacity 3000 g / 105 oz
Graduation
Normal measurement mode 1 g / 0.05 oz
MICRO mode
0 to 300 g 0.1 g
0 to 10.58 oz 0.01 oz
300 to 1500 g 0.5 g
10.58 to 52.9 oz 0.02 oz
2. Switching between g and oz.
When the power is ON, press
while pressing .
Auto Power Off
The scale is designed with an auto power-off function for energy ef ciency. If the same reading is
displayed for more than 10 minutes, the scale will automatically turn off.
Battery Replacement
When batteries are running out,
is displayed and the power is automatically turned off.
Immediately replace the batteries (all 2 batteries). Do not apply excessive force to the measuring
section when replacing batteries.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Tanita KD-321 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Tanita KD-321 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 3,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info