GB GB
2726
Troubleshooting
Page
Check pointsProblem
If you are concerned that the scale may not be functioning correctly,
please check the following points before requesting repairs.
• Have the batteries been removed, or has the AC
adapter been unplugged?
• Are the batteries run
ning low?
• Is anything stuck to the terminals of the batter-
ies?
s
P.14
Nothing is displayed
when the key i
s
pressed.
• The batteries are running out. Please replace
them immediately or use the AC adapter.
s
P.14
is displayed.
• Is any pressure being applied to the baby basket
when the power is turned on?
• Has basket been removed?
s
P.16
After the power is
turned on,
is displayed, and an
alarm sounds.
• The maximum measurable weight capacity for
the scale 15 kg is exceeded.
s
P.7
is shown
during measure-
ment.
Specifications
Accuracy at first calibration
Model
BD-815MA
Power Source
AC Adapter Centre minus MODEL A30930G CLASS2
Input Voltage : 230VAC 50Hz 65mA
Output Voltage : 9VDC ± 0.45VDC
Rated Current :300mA
No Load Voltage :12VDC ± 0.6VDC
Batteries (R6) 4 (Included) (6VDC)
Consumption Current
50mA (using the AC Adapter)
40mA (using the batteries)
Power Consumption
0.5W max (using the AC Adapter)
0.3W max (using the batteries)
Measurement System Electrical resistance method
Maximum Capacity 6kg , 15kg
Minimum Graduation
6kg : 2g
15kg : 5g
*Multiple range instrument
6kg : ±4g
15kg : ±10g
Maximum tare effect 2kg
Temperature Range of Usage +5°C / +35°C
Size
D409 W600 H157mm
Weight Approx. 4.6kg
Main material ABS resin
Made in Japan
Weighing Range
40g - 6kg
100g - 15kg
Display
panel Backlit LCD
(Backlight is on only when the AC adapter is used)
Relative Humidity 30 - 80% (without condensation)