17. ELECTRICAL SYSTEM
17-9
Inspection on Ignition Coil
Disengage the connector of the ignition coil and
the spark plug cap.
Measure the resistance between the terminals of
the primary winding.
Standard resistance: 0.17
± 10%
Remove the cap from the spark plug and measure
the resistance between the spark plug and the
primary winding.
Standard resistance:
With no cap: 3.6
± 10%
With cap: 7.3~11 K
Ignition Coil Replacement
Loosen the lock bolt and replace the ignition coil if
necessary.
Inspection of Pulse Generator
Disconnect the coupler of the pulse generator and
measure the resistance between the terminals of
green/white and blue/yellow.
Standard resistance: 50~170
Ignition coil
Spark plug
Pulse generator coupler
To this chapter contents
208


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sym Quadlander set-up at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sym Quadlander set-up in the language / languages: Dutch as an attachment in your email.

The manual is 5,59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sym Quadlander set-up

Sym Quadlander set-up User Manual - English - 3 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info