17-6
Inspection on Charging Voltage
Caution
y Before conducting the inspection, be sure that
the battery is fully charged. If undercharged,
the current changes dramatically.
y Use a fully charged battery having a voltage
larger than 13.0 V
y While starting the engine, the starter motor
draws large amount of current from the
battery.
After the engine is warmed up, replace original
battery with a fully charged battery.
Connect a digital voltmeter to the battery
terminals.
Connect an ammeter between both ends of the
main fuse.
Caution
When the probe is reversibly connected, use a
voltmeter having an indication that the current
flows from the positive or the negative direction
and the measurement should be at zero,
ammeter at one direction only.
Caution
y Does not use short-circuit cable.
y It is possible to measure the current by
connecting an ammeter between the battery
positive terminal and the cable position
terminal, however, while the starter motor is
activated, the surge current the motor draws
from the battery may damage the ammeter.
Use the kick starter to start the engine.
y The main switch shall be turned to OFF
position during the process of inspection.
Never tamper with the ammeter and the cable
while there is current flowing through. It may
damage the ammeter.
Connect a tachometer.
Turn on the headlight to high beam and start the
engine.
Accelerate the engine to the specified revolution
per minute and measure the charging voltage.
Specified Charging Current:
1.2 A / 6000 rpm
Control Charging Voltage:
14.5 + 0.5 V / 2000 rpm
Caution
To replace the old battery, use a new battery with
the same current and voltage.
The following problems are related to the charging
system; follow the instructions provided in the
checking list to correct it if any one of the problems
takes place.
(1) The charging voltage can not exceed the
voltage between two battery terminals and
the charging current is in the discharging
direction.
(2) The charging voltage and current are too
much higher than the standard values.
The following problems are not related to the
charging system; correct it if any by following
steps indicate in the checking list.
(1) The standard charging voltage and current
can only reach when the revolution of the
engine exceeds the specified rpm.
- Bulbs used exceed their rate and
consume too much power.
- The replacement battery is aged and
does not have enough capacity.
(2) The charging voltage is normal, but the
current is not.
- The replacement battery is aged and
does not have enough capacity.
- Battery used does not have enough
electricity or is over charged.
- The fuse of the ammeter is blown.
- The ammeter is improperly connected.
(3) The charging current is normal, but the
voltage is not.
- The fuse of the voltmeter is blown.
To this chapter contents
Voltmeter
Ammeter
Fuse connector
205


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sym Quadlander set-up at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sym Quadlander set-up in the language / languages: Dutch as an attachment in your email.

The manual is 5,59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sym Quadlander set-up

Sym Quadlander set-up User Manual - English - 3 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info