17. ELECTRICAL SYSTEM
17-3
Trouble Diagnosis
No voltage
y Battery discharged
y The cable disconnected
y The fuse is blown
y Improper operation of the main switch
Low voltage
y The battery is not fully charged
y Poor contact
y Poor charging system
y Poor voltage regulator
No spark produced by spark plug
y The spark plug is out of work
y The cable is poorly connected, open or
short-circuited
- Between AC.G. and C.D.I.
y Poor connection between C.D.I. and ignition
coil
- Poor connection between C.D.I. and the
main switch
y Poor main switch
y Poor C.D.I.
y AC.G. is out of work
Starter motor does not work
y The fuse is blown
y The battery is not fully charge
y Poor main switch
y Poor starter switch
y The front and rear brake switches do not
operate correctly
y Starter relay is out of work
y The ignition coil is poorly connected, open or
short-circuited
y The starter motor is out of work
Intermittent power supply
y The connector of the charging system becomes
loose
y Poor connection of the battery cable
y Poor connection or short-circuit of the
discharging system
y Poor connection or short-circuit of the power
generation system
Charging system does not operate
properly
y Burnt fuse
y Poor contact, open or short circuit
y Poor regulator
y Poor ACG
Engine does not crank smoothly
y Primary winding circuit
- Poor ignition coil
- Poor connection of cable and connectors
- Poor main switch
y Secondary winding circuit
- Poor ignition coil
- Poor spark plug
- Poor ignition coil cable
- Current leakage in the spark plug
y Incorrect ignition timing
- Poor AC.G.
- Improper installation of the pulse sensor
- Poor C.D.I.
Weak starter motor
y Poor charging system
y The battery is not fully charged
y Poor connection in the windings
y The motor gear is jammed by foreign material
Starter motor is working, but engine does
not crank
y Poor starter motor pinion
y The starter motor run in reverse direction
y Poor battery
To this chapter contents
202


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sym Quadlander set-up at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sym Quadlander set-up in the language / languages: Dutch as an attachment in your email.

The manual is 5,59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sym Quadlander set-up

Sym Quadlander set-up User Manual - English - 3 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info