482066
230
Zoom out
Zoom in
Previous page
1/244
Next page
17. Electrical System
17-10
Inspection on ignition coil
Remove the right floor garnish.
Disengage the connector of the ignition coil.
Measure the resistance between the terminals of
the primary winding.
Standard resistance: 2.8Ω±15% (20ºC)
Replacement of ignition coil
Remove the cap from the spark plug.
Loosen 2 bolts and replace the ignition coil if
necessary.
Inspection of crank position sensor
Remove luggage box (bolt×6).
Disconnect the coupler of the crank position
sensor and measure the resistance between the
terminals of green/white and blue/yellow.
Standard resistance: 80~160Ω
Caution
It is not necessary to remove the coil from the
engine during this process.
Please refer to the section 11 for disassembly of
coil.
Spark plug cap
To this chapter contents
Ignition coil
Co
upler
230


Need help? Post your question in this forum.

Forumrules
1

Forum

sym-maxsym-400

Reset search

  • May I know how to reset the time and date of maxsym 400 ? Submitted on 20-7-2021 at 02:05

    Reply Report abuse
  • Pls help to show me the step hiw to reset the time n date of sym400i Submitted on 20-7-2021 at 02:00

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sym Maxsym 400 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sym Maxsym 400 in the language / languages: English as an attachment in your email.

The manual is 10,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sym Maxsym 400

Sym Maxsym 400 User Manual - English - 34 pages

Sym Maxsym 400 User Manual - Dutch - 37 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info