HR
Blood
BP
Heart Rate
This interface automacally turns on heart rate measurement. At the same me,
the green light of PPG at the inner side is turned on and the measurement begins.
Value will be measured in 30 to 60 seconds.
Blood Pressure
Enter the interface and start the blood pressure
measurement. At the same me, the green light of PPG at
the inner side is turned on and the measurement begins.
Data will be visible in about 10 seconds and the full
measurement will take 30-60 seconds.
Hint: Sensors in the watch measure the highest and lowest value of the photo-
plethysmographic signal (PPG) - the vessel width change. It is detected by light
irradiaon and absorbance measurement. The PPG sensors are located on the
boom of the watch. To generate the PPG signals, the skin is illuminated with
green LED light, resulng in a reecon of the blood cells under the skin. The
reected poron is registered and recorded.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Swisstone SW 620 ECG at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Swisstone SW 620 ECG in the language / languages: English as an attachment in your email.

The manual is 1,81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Swisstone SW 620 ECG

Swisstone SW 620 ECG User Manual - German - 23 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info