542557
30
Zoom out
Zoom in
Previous page
1/70
Next page
28
m
NO DEC TIME
°
C
MAX
DIVE TIME
O2%
OLF
NOTE
As a s afety pr ecaution t he oxygen c alculations i n
the computer are made with an oxygen percentage
of 1% + setO
2
% .
DEFAULT NITROX SETTINGS
In the NITROX Mode, when set to standard air
(21% O
2
), the instrument can be used as an air di ve
computer. It remains in this air mode until the O
2
%
setting is adjusted to any other percentage of oxygen
(22% - 50%).
NOTE! The computer will automatically revert to
the air (21% O2) setting when a ne w dive series is
started, if it is not set to any other mix during the last
two hours. When the oxygen percentage is set for air,
the computer will retain this setting.
Manually entered values for oxygen percentage are
retained for about two hours after the setting if a dive
series has not started. In case a dive series is started,
the set v alue is retained until a ne w dive series is
started or a new value is entered manually.
The default setting for maximum oxygen partial pres-
sure is 1.4 bar, however you are able to set it between
the range of 1.2 - 1.6 bar.
3.4.2. Oxygen Displays
If set to Nitrox mode the NITROX display, with all
labeled oxygen information and the label NITROX, is
shown after activation, and before the Dive Planning
Mode. The Nitrox display shows (Fig. 3.20.):
the oxygen percentage, labeled with O
2
%, is
shown in the left side of the center window
the set oxygen partial pressure limit, labeled
with PO
2
, is shown in the upper right display
the maximum allowed depth based on the set
oxygen percentage and partial pressure limit
the current oxygen toxicity exposure shown
with an Oxygen Limit Fraction (OLF) bar
graph along the left side of the display (instead
of the CBT).
Fig. 3.20. Nitrox display.
Maximum depth based on
set O2% (21%) and PO2 (1.4
bar) is 54.1 m [177 ft].
Fig. 3.21. Surface display in
the Nitrox mode
PO2
O2%
OLF
m
Fig. 3.22. Diving in Nitrox
mode. The O2% is set to 32%.
°
C
TIME
DIVE
m
OLF
O2%
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Suunto GEKKO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Suunto GEKKO in the language / languages: English as an attachment in your email.

The manual is 2,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Suunto GEKKO

Suunto GEKKO User Manual - German - 70 pages

Suunto GEKKO User Manual - Dutch - 70 pages

Suunto GEKKO User Manual - Spanish - 70 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info