704206
6
Zoom out
Zoom in
Previous page
1/52
Next page
80-0067-00-MO-RevJ 2019-01-30 SunTech CT40 User Manual | 6
Pulse Oximetry (SpO2)
ChipOx SpO2 Module: Use only pulse oximeter (SpO2) sensors supplied by SunTech Medical or original Nellcor® pulse
oximeter (SpO2) sensors supplied by Covidien® (except for forehead reflectance sensors).
Masimo® SpO2 Module: Use only original Masimo® pulse oximeter (SpO2) sensors and cables.
Check the application site of the SpO2 sensor frequently to confirm proper positioning of the sensor and to check the
circulation and skin sensitivity of the patient.
Wireless Networking
When connecting this device to a wireless network, it is important to use only the hardware specified by SunTech
Medical (see Accessories section for details). Unsupported USB accessories, including unsupported Wireless
adapters, have been intentionally disabled and will not function with this device.
Possible Adverse Reactions
In the area of the BP cuff or SpO2 sensor, allergic exanthema (symptomatic eruption) may result, including the
formation of urticaria (allergic reaction including raised edematous patches of skin or mucous membrane and
intense itching) caused by the fabric material of the cuff or sensor.
Following the application of the BP cuff, petechia formation (a minute reddish or purplish spot containing blood that
appears in the skin) or Rumpel-Leede phenomenon (multiple petechia) may appear on the arm, which may lead to
idiopathic-thrombocytopenia (spontaneous persistent decrease in the number of platelets, associated with
hemorrhagic conditions) or phlebitis (inflammation of a vein).
Warnings and Cautions
WARNING: Do not attach the cuff to a limb being used for IV infusions or any other intravascular access, therapy or
an arteriovenous (A-V) shunt. The cuff inflation can temporarily block blood flow, potentially causing harm to the
patient.
WARNING: Pressurization of the cuff can temporarily cause loss of functionality of SpO2 if simultaneously using
device on the same limb.
WARNING: Not designed for neonates.
WARNING: Do not apply the BP cuff to a limb being used for IV infusions as the cuff inflation can temporarily block
the infusion, causing harm to the patient.
WARNING: Check frequently by observing the limb that operation of the AUTOMATED SPHYGMOMANOMETER does
not result in prolonged impairment of the circulation of the patient.
WARNING: The cuff should not be applied over a wound as this can cause further injury.
WARNING: The cuff should not be placed on the arm on the side of a mastectomy. In the case of a double
mastectomy use the side of the least dominant arm.
WARNING: The CT40 is NOT defibrillator protected.
WARNING: Do not use in the presence of flammable anesthetics or other flammable substances in combination with
air, oxygen-enriched environments, or nitrous oxide.
WARNING: Do not use the device if it has failed its diagnostics self-test, or if it displays a greater than zero pressure
with no BP cuff attached or a value of oxygen saturation with no SpO2 sensor attached.
WARNING: Do not use if device is dropped and/or damaged. Have a qualified service representative check the unit
before using again.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for SunTech CT40 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of SunTech CT40 in the language / languages: English as an attachment in your email.

The manual is 2,09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of SunTech CT40

SunTech CT40 User Manual - German - 49 pages

SunTech CT40 User Manual - Dutch - 52 pages

SunTech CT40 User Manual - French - 50 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info