Caution: The monitor does not contain any user-serviceable parts. The repair of the instrument must be
conducted by technical personnel authorized by the manufacturer.
2.3 Important Notes for Safety
Patient Number
The monitor can only be applied to one patient at one time.
Interference
Do not use a mobile phone in the vicinity of the monitor. High level of electromagnetic radiation emitted from
such devices may result in strong interference with the monitor performance.
Protection against ingress of liquid
To avoid electric shock or device malfunction, liquids must not be allowed to enter the device. If liquids have
entered the device, take it out of service and have it checked by a service technician before it is used again.
Accuracy
If the accuracy of any value displayed on the monitor or printed on a printout paper is questionable, determine
the patient’s vital signs by alternative means. Verify that the equipment is working correctly.
Alarm
Do not rely exclusively on the audible alarm system for patient monitoring. Adjustment of alarm volume to a
low level or off during patient monitoring may result in a hazard to the patient. Remember that the most
reliable method of patient monitoring combines close personal surveillance and correct operation of
monitor.
The functions of the alarm system for monitoring the patient must be verified at regular intervals.
Before Use
Before putting the system into operation, please visually inspect all connecting cables for signs of damage.
Damaged cables and connectors must be replaced immediately.
Before using the system, the operator must verify that it is in correct working order and operating condition.
Periodically, and whenever the integrity of the product is in doubt, test all functions.
Cables
Route all cables away from patient’s throat to avoid possible strangulation.
Disposal of package
When disposing of the packaging material, please observe the applicable waste control
regulations and keep packaging material out of children’s reach.
Leakage current test
When interfacing with other equipment, a test for leakage current must be performed by qualified biomedical
engineering personnel before using with patients.
Battery
The device is equipped with a battery. The battery discharges even when the device is not in use. Store the
device with a fully charged battery and take out the battery, so that the service life of the battery will not be
shortened.
Disposal of accessories and device
Disposable accessories are intended for single use only. They should not be reused as performance could
degrade or contamination could occur.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for SunTech CT 50 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of SunTech CT 50 in the language / languages: English as an attachment in your email.

The manual is 2,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of SunTech CT 50

SunTech CT 50 User Manual - German - 85 pages

SunTech CT 50 User Manual - French - 86 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info