TRANSFORM unit
deactivates.
On reaching the set required temperature, the
TRANSFORM unit switches off automatically. Check
manual setting of the required temperature as well as the
TIMER setting.
How is the m² or
m³ data of the
manufacturer
calculated
The m² or m³ data of the manufacturer for the various
TRANSFORM units are average values related to a
room height of 2.5 metres. It must be considered that
such data can be clearly underscored or exceeded
under certain circumstances. Circumstances which work
against efficiency of the TRANSFORM units include e.g.
bad insulation of the building, large window areas, south
facing, attic apartment, many additional heat sources,
such as e.g. number of persons, EDP, light, kitchen
units, washing units etc.
TRANSFORM unit
does not cool
correctly
You achieve the most effective and economical cooling
comfort if you already cool the room to be cooled when
the room temperature is not yet heated up. Air
conditioners operate more effectively if the temperature
is to be maintained. To drastically cool the air and
inventory in a fully heated room requires much more time
and energy.
E1 Room temperature
outside the function
range:
Room temperature
inside the function
range:
Observe all data in these operating instructions
concerning function range.
Temporary error of start temperature. Please switch the
TRANSFORM unit off and start it again after approx. 30
minutes. If the error occurs continuously, the
TRANSFORM unit requires specialist inspection.
E2 Temperature of the
cooling agent lines too
high or too low
Temporary error on measuring output temperature.
Please switch the TRANSFORM unit off and start it
again after approx. 30 minutes. If the error occurs
continuously, the TRANSFORM unit requires specialist
inspection.
E3 Incorrect signal This error message in the cooling function refers to too
high ambient temperatures and in the heating function to
too low ambient temperatures. Please observe the
instructions relating to ideal operation of the
TRANSFORM unit. This may also be a temporary error
measurement between the start and output temperature.
Please switch the TRANSFORM unit off and start it
again after approx. 30 minutes. If the error occurs
continuously, the TRANSFORM unit requires specialist
inspection.
E4 Water tank full If the water tank is full, the warning sign "E4" appears in
the display. To restart operation of the TRANSFORM
unit, please remove the plug of the condensation water
outlet to allow water to leak out. Please use an
appropriate collection tank. When the water has been
completely removed, please start the TRANSPORT unit
again. The TRANSFORM unit can now be used as
usual.
DF De-icing mode This procedure is completely normal and protects the
system from icing and failure. The unit starts
automatically after approx. 15 minutes again (depending
on the function setting). This procedure repeats itself
regularly.
SPARE PARTS AND ACCESSORIES SUPPLY (FAST CONVENIENT SUPPLY)
You can obtain spare parts and accessories for your TRANSFORM unit from your local dealer. And
at our website
www.suntec-wellness.de
you will find further information on individual
accessory products as well as information on obtaining our spare parts quickly and conveniently.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Suntec Wellness Transform 14000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Suntec Wellness Transform 14000 in the language / languages: English as an attachment in your email.

The manual is 1,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info