Using your healthy air cleaner
Your new healthy air cleaner comes ready to use. The unit’s particle screen and multi-
function cartridges are already installed. Simply follow these easy steps to begin using your
healthy air cleaner.
1. Place the unit in safe, dry location about 3-4 feet off the ground.
2. If you wish to use the optional fragrance function proceed as follows; otherwise skip
to step 3. Press gently on the fragrance compartment lid. This is part of the top grill
assembly, and is inset into the right side of the grill. Once pressed the cover should
release and pop up. Remove and set this cover aside. Next, take out the fragrance
canister inside and remove its slotted cap. Remove and discard the canister’s inner
lid, and put slotted cap back onto the canister. Return the canister to the fragrance
compartment and reinstall the fragrance compartment cover. Make sure it “catches”
and fits snugly in place.
3. Plug in the unit.
4. To turn the unit on, simply press the “POWER” button on the front.
5. To activate the anion cleaning function, simply press “ANION”. It is recommended
that this be on whenever using your new air purifier.
6. Select a speed setting (“SPEED”) by choosing high (H), medium (M), or low (L).
Press the button repeatedly until the desired setting indicator lights. The constant
clean setting (L) is useful for continuous cleaning, and is quiet enough for use in
bedroom at night.
7. To choose a timed program, select an interval using the “time” button. This may be 2,
4, or 8 hours. Press the button repeatedly until the desired time interval indicator
lights. If a time interval is not selected the unit will operate continuously.
8. Each of the remote control buttons correspond to a healthy air cleaner function. This
allows you to directly access a specific function without “cycling through” the options
as you would if were using the buttons on the unit. For example, to select the 8 hours
time setting, you could simply press the “8h” (8) button on the remote control. To
activate anion technology, you would press “ANION”. The use of the remote control is
optional; the healthy air cleaner can be fully operated either with or without it.
Care and cleaning guidelines
Your healthy air cleaner is designed to be long lasting and easy to care for. Just follow these
steps.
The healthy air cleaner has only two components that should require regular attention. These
are the particle screen and the dual, multifunction cartridges. The particle screen is reusable
and only needs periodic cleaning. The long-lasting multi-function cartridge should be
replaced about every 6-12 months or as indicated.
Your unit also comes with a fragrance canister; however, this is optional and is not required
for the unit’s successful operation. Before opening or cleaning the unit, always unplug the
unit from the wall outlet first.
1. For access instructions to replace the fragrance canister, follow the instructions under
“using your healthy air cleaner”. Note that any similar type of fragrance may be used.
Such replacements often may be found locally, particularly in automotive parts and
accessory stores.
2. You will want to clean the unit’s particle screen (pre-filter) about once a month or
when indicated. To clean the unit’s particle screen (pre-filter), you should first remove
the air intake cover (side grill). The release catch is at the bottom of the grill. To
remove the cover, inspect the bottom catch carefully, and then gently lift up on it
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Suntec Wellness Air Care 200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Suntec Wellness Air Care 200 in the language / languages: English as an attachment in your email.

The manual is 0,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info