TROUBLESHOOTING
Problem
Cause
Solution
Hot air comes from the air outlet
-----------
The dehumidifier has no cooling
function; the air comes out of
the condenser. This is not a
defect.
The unit does not work.
Is the unit plugged in?
Plug in the unit.
Check the ambient
temperature.
The temperature should be
between 5 - 35°C.
Does the "tank full" indicator
(water tank is full or misplaced)
light up?
Empty the water tank and set it
to the correct position again.
The device does not
dehumidify.
Is the air inlet or outlet blocked?
Check the air inlet and outlet
and remove any obstructions.
Is the ambient temperature or
relative humidity too low?
Please check the settings on
the unit. If the set humidity is
below the ambient humidity and
/ or 20%, the unit stops
dehumidifying.
The air does not flow out.
Is the air filter dirty?
Clean the air filter as described
in the manual.
Is the air inlet or outlet blocked?
Check the air inlet and outlet
and remove any obstructing
objects if necessary.
Loud noises during start up.
If the device was placed awry or
unstable?
Place the unit on a stable flat
surface.
Is the air filter dirty?
Clean the air filter as described
in the manual.
Error Code
E2
Humidity sensor damaged or
failed.
Please contact your dealer.
CL
Room temperature is below 5°
C.
The compressor switches off
under this condition. The fan
continues to run.
CH
Room temperature is above
35°C.
The compressor switches off
under this condition. The fan
continues to run.
LO
If the relative humidity in the
room is below 20%.
The compressor switches off
under this condition. The fan
continues to run.
HI
When the relative humidity in
the room is above 90%.
The compressor and fan
continue to run under this
condition.
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Suntec Klimatronic DryFix 20 MAX - 16349 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Suntec Klimatronic DryFix 20 MAX - 16349 in the language / languages: English, German, Dutch, French, Italian, Polish, Portuguese, Spanish as an attachment in your email.

The manual is 2,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info