Child lock. Please press and hold the button to unlock/lock all buttons.
Please press this key to select the desired fan speed.
Please press this button to switch on the sleep mode or hold the button for 3
seconds to reset the filter change indicator.
Press these buttons to change the timer or humidity level settings.
OPERATION INSTRUCTIONS
Attention: These functions are only available when the room temperature is between 5°C-35°C and the
humidity is between 20%-90%.
Switching the device on/off
- Please plug in the power plug of the dehumidifier.
- Please press the STAND-BY button to turn on the device.
- The unit will start with high fan speed and humidity level setting of 50%.
- Please press the STAND-BY button again to deactivate the unit. The fan will continue to run for
30 seconds.
Timer
Power off time:
- Please press the TIMER button while the unit is running to set the off time.
- The time can be set by the hour (0-24h) with the up / down " " buttons.
Switch-on time:
- Please press the TIMER key while the device is switched off to determine the switch-on time.
- The time can be set by the hour (0-24h) with the up / down keys " ".
Deactivate timer:
- Please press the up / down button repeatedly until '00' is shown on the display.
Continuous dehumidification - Auto dehumidification
- Please press the MODE button to select between continuous and auto dehumidification mode.
- In continuous dehumidification mode, the unit is always set to high ventilation speed and 20%
humidity. This cannot be changed in this mode.
- In automatic dehumidification mode, the unit automatically starts with a dehumidification level of
50%. You can set the desired dehumidification level by operating the keys.
- If the relative humidity in the room is higher than the set dehumidification level (+3%), the unit
runs at a higher fan speed.
- If the relative humidity in the room is lower than the set dehumidification level (-3%), the
dehumidification function switches off and the fan runs for 30 seconds.
Up/down keys
- Please press these buttons to set the desired humidity level or timer.
- Up button adds 5% (30% - 80%) humidity or adds 1 hour at timer.
- Down key subtracts 5% (30% - 80%) humidity or subtracts 1 hour from the timer.