shut off automatically, but the fan will still move to ensure air is not stale in the room. The unit will use only a minimal
amount of energy in fan mode.
When the humidity is equal or higher than user selected humidity the compressor will restart once the 3-minute delay
compressor protection expires.
We recommend you to leave the unit to rest for about 10 minutes before using it again, to protect the compressor.
Auto-Restart: If the unit stops off unexpectedly due to the power cut, it will restart with the previous function selected.
Laundry: Set the humidity level to 35%-50% RH. 35% is very dry and the unit will work until water tank is full. Set the fan
to HIGH-function and the louvres to swing mode or 45 °C, directing the airflow onto clothes / laundry dryer. Please do not
place your laundry directly on the device. Make sure that there is nothing blocking the hot air exhaust airflow and place
them 1,5 meters away from the device.
Condensation Drainage
Water Tank:
- When the tank is full the indicator light will flash and the unit will beep.
- Turn the device off and unplug the unit.
- Slowly pull out and empty the water tank.
- Reinsert it into the dehumidifier.
Note: To prevent growth of mould, mildew and bacteria, clean the tank every few weeks. Fill the tank with clean water
and add a little mild detergent. Swish it around and then empty the tank and rinse. Do not use a dishwasher to clean
the tank.
Continuous Draining:
- Please find on the back of the unit the drain outlet.
- Remove the plastic bung.
- Please insert the pipe (not included) into the drain outlet, direct the pipe to a suitable drainage point and let the water
flow out smoothly.
- Make sure that the connection between the pipe and the drain outlet is tight, so that there is no leak.
Maintenance and care
1. Please turn the device off.
2. Unplug the unit from the power outlet before cleaning.
3. To clean the dust filter, please follow the instructions:
- Remove the filter housing from the unit and pull out the filter from the frame.
- If the filter is dusty, use a vacuum attachment or a soft brush to clean.
- Wash the filter with warm water and dry it with a soft cloth.
- Leave it to dry before reinserting it into the filter frame.
4. Clean the unit with a wet cloth and then wipe it with a dry cloth.
5. Please do not use any chemical solvents or hot water.
6. If the unit will not be used for a long time period, turn it off, unplug it, cover the unit and keep it in a dry and safe
place.
Troubleshooting
Issue
Cause
Solution
The dehumidifier does not extract
much water if the temperature is
low.
Normal Operation
The compressor works best in temperatures above
15°C. If the temperature is lower than 15°C and the
air is dryer than the setting on the unit, the device will
not extract water.
Cold and/or hot air comes out from
the air outlet.
Normal Operation
When the unit is in dehumidifying mode it absorbs
humid air from the room and freezes it to reduce
humidity in the room.
Is the tank-full indicator activated?
Tank full or the tank has
not been properly
inserted.
Empty the tank and make sure the tank is properly
inserted in the unit.
No function.
Is the plug properly
inserted in the socket?
Insert the plug into the socket and press the
POWER-button.
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Suntec DryFix 20 PRO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Suntec DryFix 20 PRO in the language / languages: English, German, Dutch, French, Italian, Polish, Portuguese, Spanish as an attachment in your email.

The manual is 2,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info