514900
18
Zoom out
Zoom in
Previous page
1/52
Next page
13 SUNRISE F16 Issue 8
Pilot control
Proportional control
Your wheelchair is fitted as
standard with a side mounted
proportional control (Fig. 13). This
supplies a smooth flow of electrical
power to your motors via the
movement of the joystick. Push the
joystick gently forward to increase
forward speed.
When the joystick is at its full extent
your powerchair is travelling at full
speed as set by the speed setting
lever on the rear of the control box.
As the joystick is released the
wheelchair will automatically
engage motor brakes and stop. In
front of the joystick is a green push-
button switch which turns the
controller on and off. Do not use
this switch to stop the wheelchair
except in an emergency.
Adjustable speed setting
The maximum power and speed of
your wheelchair can be adjusted by
turning the power setting control
lever anticlockwise to reduce
speed, and clockwise to increase
speed, this is useful when learning
or in tight situations (Fig. 14).
Fig. 13
Fig. 14
On/Off button
Battery gauge
Joystick
Adjustable speed setting
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sunrise Medical F16 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sunrise Medical F16 in the language / languages: English as an attachment in your email.

The manual is 1,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info