807015
9
Zoom out
Zoom in
Previous page
1/52
Next page
16 17
FIRST USE / OPERATION
Please note: never transport the device with a full water tank.
Possible hazards:
too much water from water tank comes into the Main Base (12), this overloaded water level
will cause dramatic reduction of mist output of the device.
water can easily come out from the Main Base (12).
the water tank can fall off from the Main Base (12) and get damaged due to the heavy weight
from the water (and water can leak on to the floor).
1. For this reason, Main Base (12) of the Stylies GALAXY humidifier should be placed first
with empty Water Tank (2/11) in a suitable location.
2. When the device is in the desired location: Fill Water Tank (2/11) with fresh water and
screw the Tank Cover (14) back on firmly and check that it is sealed properly. Place Water
Tank on base.
3. Plug Power Cable (13) into the power socket.
4. Switch on the device by pressing the On/Off switch on the Control Panel (4), the con-
trol display appears blue.
Caution: If the red «Low water» warning lights up, the humidifier cannot be switched on.
Check the water level in the tank. It may take several minutes to refill the water collector (21) if
necessary (the red light then goes out).
5. The Mist Cap (1) can be turned 360° to have an even distribution of moisture. Never point
the nozzle at walls or furniture, etc.
6. On the Display panel (8), it shows the current humidity level in the room, e.g.. «45 % RH».
The desired air humidity level can be selected by pressing the humidity button on the Con-
trol Panel. Settings are in 5% stages from 45 % to 75 % rel. air humidity. «CO» means contin-
uous operation without automatic control. We recommend 45-60 % rel. air humidity for living
areas.
When the «Auto» light (7) stops flashing, the setting has been saved and the current air humid-
ity is displayed again. The humidifier starts automatically as soon as the humidity is lower than
the setting, and stops when it is higher.
Note: If «CO» (continuous operation) is set, the humidifier WILL NOT STOP OR RESTART auto-
matically.
7. Press this key to set the mist quantity in three stages (1 = low, 3 = high).
8. Press thy key to dim the LED light. Press it again to turn the light on.
9. «Timer»-key for setting the time until automatic shutdown. (Press in 1-hour steps, e.g. «2:00»
for two hours). The display then shows «Timer» (5). The display goes out after reaching shut-
down time. Possible settings: «1:00 - 12:00» hours, or «0:00» to quit timer.
10. «Low water» warning: this red LED lights up if the water collector is empty or too low. In this
case turn off the «On/Of power switch and fill the tank with fresh water. Then replace the tank
ln the base and turn the power on again.
Note: When you remove the tank, some water will flow out of the decalcifier cartridge. Then
turn the tank upside down and carry it with the lower handle (16). To prevent damage, always
turn off the power when the «Low water» warning lights up.
CLEANING PROCEDURE
Switch off the device and unplug the power cable from the socket before all maintenance
work and after each use.
Never submerge the device in water (this can result in short-circuiting). To clean the device,
simply wipe it with a damp cloth and then dry it thoroughly. Always ensure the power cable
has been unplugged beforehand.
Descale the humidifier as appropriate for the hardness of the water, but at least once a
week: First remove the water tank and clean it with a brush. Descale the water collector
(22) in the base with a standard descaler and then rinse it thoroughly. Make sure no water
penetrates inside. Reassemble the device completely before use.
Remove the mist chamber (23) by gently turning anticlockwise and lifting. Also remove the
beige outlet basket (25). Thoroughly rinse both components, and reassemble in the opposite
order. Make sure the mist chamber is firmly seated.
Thoroughly rinse out the water tank on a regular basis.
Replace Descaler Cartridge (15) every 1-2 months as appropriate for the hardness of the
wa t er.
Descaler Cartridge and Water Hardness
The life-span of the cartridge is dependent on the hardness of the water. This can be
tested using the test strip supplied (the test strip is placed on the reverse side of this
instruction manual).
Dip the test strip into the water for one second.
After approx. one minute, the result can be seen on the measuring strip. Some of the
green areas will change their colour to pink. The number of pink areas corresponds to the
hardness of the water.
Example: If there are three pink areas, the water has a hardness of «3».
Number of
pink areas
Water
hardness
Hardness (°dH) Cartridge needs replacing
after days/litres
(approx for 3 litres per day)
0/1 soft from 4°dH 120 days / 360 litres
2medium from 7°dH 60 days / 180 litres
3slightly hard from 14°dH 40 days / 120 litres
4very hard from 21°dH 20 days / 60 litres
A simple test can be carried out to determine whether the cartridge is functioning correctly:
hold a small mirror in the mist coming out from the unit for a few seconds. If a white deposit
has been left on the mirror (a sign of lime scale), the cartridge needs to be replaced.
Silver Cube
Before attaching the water tank, insert the «Silver Cube» in the base in the position (20)
indicated. (the «SilverCube» is works fitted).
The «Silver Cube» with its patented technology prevents the growth of bacteria and germs. It can
be used for a maximum of one season, and must be replaced at the start of the next heating
season (i.e. when the weather becomes cold). Despite using the «Silver Cube», you should replace
the water on a daily basis.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stylies Galaxy at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stylies Galaxy in the language / languages: English, German, Dutch, French, Italian, Polish, Swedish, Spanish as an attachment in your email.

The manual is 8.33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info