813458
4
Zoom out
Zoom in
Previous page
1/44
Next page
4
GENERAL
Model:
Vision Small / Small T
Vision Midi / Midi T
Vision Medium Slimline
Vision Medium
Small
Small T
Midi
Midi T
Medium Slimline
Medium
Nominal Heat Output Wood kW 5.0 5.0 5.0 5.0 5.0 7.0
Solid Fuel kW 5.0 5.0 5.0 5.0 5.0 8.2
Efficiency Wood % 79.9 80.2 79.5 78.4 76.5 74.8
Solid Fuel % 80.1 79.8 78.6 78.4 79.4 80.8
CO @ 13% O2Wood % 0.14 0.11 0.11 0.12 0.11 0.12
Solid Fuel % 0.07 0.03 0.04 0.11 0.08 0.08
Weight Multi-fuel Kg 61.5 65 71 80 86 95
Recommended Fuels Wood Seasoned Wood (less than 20% moisture content)
Solid Fuel Briquette smokeless fuel suitable for closed appliances
(Ancit-Phuracite-Taybrite-Maxibrite-Homefire Ovals)
As tested to the requirements of EN 13240 for intermittent operation
FLUES
Flue/Chimney Size
Note: If the appliance has not been
commissioned as a DEFRA smoke
controlled appliance then the flue
system should be 153mm (6").
Without flue liner Round
(Diameter)
mm 153 153 153 153 153 153
inch 6 6 6 6 6 6
Without flue liner system (Square)
mm 135 135 135 135 135 135
inch
With Liner of Factory made system
(diameter)
installed in accordance with
manufacturers instructions
mm 150 150 150 150 150 150
inch 6 6 6 6 6 6
Flue/Chimney
minimum height**
All products
**must be 4.5m from the hearth
to the top of the flue, with
no horizontal sections and a
maximum of 4 bends. Bends
must have angles of less than 45
degrees from the vertical.
m 4.5 4.5 4.5 4.5 4.5 4.5
feet 15 15 15 15 15 15
Flue Draught
Min
Pa
10 10 10 10 10 10
Nominal 12 12 12 12 12 12
Max 20 20 20 20 20 20
Flue Gas Mass Flow Wood g/s 4.0 4.0 3.8 4.3 5.9 6.5
Solid Fuel g/s 3.4 3.0 3.4 4.0 3.8 4.7
Flue Gas Temperature at Spigot/
Socket
Wood oC 283 272 312 303 261 329
Solid Fuel oC 297 307 338 278 272 312
Flue Outlet Size
(Top or Rear Option) All mm 128 128 128 128 153 153
inch 5 5 5 5 6 6
European Min Spec for Chimney Flue - T400 N2 D 3 G50
VENTILATION
A) Traditionally Built Homes
• Where leakage is greater than 5m3/hour/m2.
• Ventilation normally required = 550mm2 per kW output over 5kW
B) Modern Construction Homes
• Where leakage is less than 5m3/hour/m2.
• Ventilation normally required = 550mm2 per kW Wood Solid
Fuel
AAdditional Ventilation
mm2 None None None 1100 1650
cm2 None None None 11 16.5
in2 None None None 1.77 2.6
BAdditional Ventilation
mm2 2750 2750 2750 3850 4400
cm2 27.5 27.5 27.5 38.5 44
in2 4.4 4.4 4.4 6.2 7.1
For full technical details on ventilation see Technical Appendix
ESSENTIAL INFORMATION - VISION MULTI-FUEL STOVE
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stovax Vogue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stovax Vogue in the language / languages: English as an attachment in your email.

The manual is 5.99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Stovax Vogue

Stovax Vogue User Manual - English - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info