Getting Started
AIR CONTROLS
Triple Air Systems
Several Stovax appliances have triple air systems providing
cleaner burning, and greater efficiency and control,
see Diagram 2.
1) Airwash - air drawn over the window cleans the glass.
The source of Primary Combustion air when
burning wood.
2) Primary Air - for use initially when establishing fires and
the main air supply when burning solid fuels.
3) Cleanburn - Secondary air is preheated through a heat
exchanger to combust unburned hydrocarbons, providing
a cleaner and more efficient burn.
2
1
3
2
Manually operate the following air controls using the tool
provided.
Do not place tool on hot surfaces (e.g. top of appliance).
3
Thermostatic
Control
Secondary Control
Pull - OPEN
Push - CLOSE
Airwash Control
CLOSE OPEN
Primary Control
CLOSE OPEN
The Secondary Air Control is located below the appliance
door, under the ashlip. This control is used to adjust the
amount of 'Cleanburn' combustion air injected into the
burning flames. Push air control in to reduce and pull to
increase the flow of air.
DOOR OPERATION
IMPORTANT: Stovax provide gauntlet style gloves
for the users protection from heat and any sharp
edges when using the appliance.
For your safety ensure that gloves are always
worn when opening, operating, refuelling or
handling internal metalwork.
Use a protected gloved hand and tool provided to operate.
DO NOT OPEN THE DOOR WITH BARE HANDS
DO NOT OPEN THE DOORS WHEN THE FIREBOX IS
FULL OF FLAMES - WAIT FOR THEM TO DIE DOWN.
To Open and Close
Fit tool into side slot and lift to open
4
HEATING & HOT WATER SYSTEM CONTROLS
CONTROLS, GENERAL
1.15 As part of the installation of this appliance controls will have
been fitted to the heating and hot water system in order to
provide two functions:
To control the comfort level in the house, see 1.16.
To maintain safety in the event of misuse or mechanical
failure, see 1.18.
COMFORT CONTROLS
1.16 A programmable timer switches the pump on when heat is
required and off when it is not.
The timer, when combined with a room thermostat and / or
thermostatic radiator valves, enhances the comfort levels in
the house.
Some room thermostats combine the function with the timer
and can be programmed to reduce the room temperature
rather than turning the system off. This is effective in
not allowing rooms to become too cold and speeding up
recovery time.
1.17 The hot water cylinder can also be fitted with a thermostatic
valve which turns off the flow when the cylinder has reached
the desired temperature, but the heat leak radiator will have to
be bigger to cope with the extra load when the tank is isolated.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stovax View High Output Boiler Stoves at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stovax View High Output Boiler Stoves in the language / languages: English as an attachment in your email.

The manual is 4.95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info