Technical Appendix
3. Ventilation
3.1 Many older buildings are sufficiently ventilated by natural
leakage of air to provide suitable air supply for an appliance
of 5kW output or less.
Modern building techniques have reduced the amount of air
that leaks in or out of a house. A modern construction with
an air tightness of less than 5m3 per hour per m2 requires
an air vent for ALL solid fuel appliances including those with
a rated heat output of less than 5kW.
NOTE: The air leakage of a modern house is tested at
the completion of construction and a certificate issued
confirming this.
3.2 This appliance requires a constant supply of air to maintain
proper combustion and effective flue performance.
3.3 An inadequate air supply can result in poor combustion and
smoke entering the room which is potentially dangerous.
3.4 This supply of air can come from either:
— Purpose provided ventilation.
— Some Stovax appliances can also be fitted with an
optional outdoor air kit which allows air to be drawn in
from the outside.
3.5 The amount of air required must comply with local building
regulations and the rules in force.
3.6 If spillage is detected during commissioning then there may
be insufficient natural ventilation and an additional air supply
will be necessary.
3.7 Permanent air vents should be non-adjustable and
positioned where they are unlikely to be become blocked.
3.8 If vents open into adjoining rooms or spaces there must be
an air vent of at least the same size direct to the outside.
3.9 Site the vents where cold draught is unlikely to cause
discomfort. This can be avoided by placing vents near
ceilings or close to the appliance (See diagram).
3.10 Extractor fans or cooker hoods must not be placed in the
same room or space as this can cause the appliance to emit
fumes into the room.
3.11 Increase air supply provisions where a room contains
multiple appliances.
3.12 If any checks reveal problems do not proceed with the
fitting of the appliance until they have been rectified.
4. Minimum Dimensions - Hearth
4.1 The appliance must stand on a non-combustible
constructional hearth which is at least 125mm thick with the
minimum dimensions as shown in diagram.
As this appliance can be installed in an elevated setting it is
recommended to increase the 225mm hearth depth to safely
contain any falling logs or embers. The higher the appliance
is installed the deeper the hearth should be to protect the
floor.
4.2 The building must have a suitable load-bearing capacity for
the hearth and appliance. Consult a structural engineer for
advice before proceeding.
4.3 When fitting into an existing hearth check that the appliance
complies with current construction regulations and is at least
the minimum sizes shown.
4.4 If there is no existing fireplace or chimney it is possible to
construct a suitable non-combustible housing and hearth
setting. The flue must be installed in accordance with all
local and national regulations and current rules in force.
4.5 Check if adding a new chimney to your property requires
planning permission.
4.6 Some houses are built using a timber frame construction
with high levels of thermal insulation. Isolate the appliance
from combustible materials, and provide sufficient ventilation
to maintain the heating efficiency.
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stovax View Freestanding at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stovax View Freestanding in the language / languages: English as an attachment in your email.

The manual is 6.47 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Stovax View Freestanding

Stovax View Freestanding Usermanual and installation guide - English - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info