813428
18
Zoom out
Zoom in
Previous page
1/44
Next page
18
Installation Checklist
5. Minimum Builders Opening
To make installation easier make the opening slightly larger than
the minimum requirements where possible.
*see note
5
AFront
B
C
View 7
A 410mm
B 560mm
C 355mm
6. Fire Surround Clearances
If the appliance is to be fitted with a fire surround, use the
minimum clearances, see Diagram, between any point of
the appliance and any combustible material. Stovax produce
a selection of surrounds and details can be obtained from
your local supplier.
150
mm
300mm
150
mm
6
6.1 We recommend you obtain expert advice before proceeding
with work of this nature.
6.2 Some finishes may discolour with heat and some lower
quality products may distort, or crack, when in use.
3. Boiler Output Charts
3
4. Minimum Dimensions - Hearth
150
150
225
500
789
Superimposed Hearth
(or area to be free of combustible
material)
Constructional
Hearth
4
4.1 The appliance must stand on a non-combustible
constructional hearth which is at least 125mm thick with the
minimum dimensions as shown in diagram.
4.2 If this appliance is installed in an elevated setting it is
recommended to increase the 225mm hearth depth to safely
contain any falling logs or embers. The higher the appliance
is installed the deeper the hearth should be to avoid
scorched floor coverings.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stovax View 7 Inset High Output Boiler Inset at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stovax View 7 Inset High Output Boiler Inset in the language / languages: English as an attachment in your email.

The manual is 4.77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info