813434
3
Zoom out
Zoom in
Previous page
1/12
Next page
3
SITE REQUIREMENTS
1. GENERAL REQUIREMENTS
Before installation and/or use of this appliance please read
these instructions fully and carefully to ensure that you have
fully understood their requirements.
It is important to remember the full instruction manual
supplied with this appliance deals with the installation of a
cassette insert. Using this supplement and the appliance to
create a Bench Standing changes the installation requirements
to that of a freestanding stove. As a result there are several
changes to the site requirements that must be adhered to when
locating the product.
The following section gives advice on clearances to
combustible materials in order to ensure a safe installation
The appliance must be fitted by a registered installer* or approved
by your local building control officer.
Works must be carried out with care to meet the requirements
of Health and Safety and comply with the Health and Safety
rules**, and any new regulations introduced during the lifetime of
these instructions. Particular attention should be drawn to:
Handling: The appliance is heavy. Adequate facilities
must be available for loading, unloading and on site
handling.
Fire Cement: Some fire cement is caustic and must not
come into contact with the skin. Protective gloves
must be worn. Wash hands thoroughly with plenty of
water after contact with skin.
Asbestos: This appliance contains no asbestos. If there
is the possibility of disturbing any asbestos in the
course of installation seek specialist guidance and use
appropriate equipment.
Metal Parts: Take care when installing or servicing the
stove to avoid personal injury.
A faulty installation can cause danger to the inhabitants and
structure of the building.
For users of this appliance:
Your building insurance company may require you to inform them
that a new heating appliance has been installed on your property.
Check that your cover is still valid after installing the appliance.
2. MINIMUM DIMENSIONS - HEARTH
IMPORTANT: THIS APPLIANCE MUST BE FITTED TO A
BENCH BEFORE LOCATING ON A HEARTH.
A
A
PR9310
The perimeter of the hearth should be
clearly marked if flush with flooring
B
A
1
Model
Dimensions
A B
Studio 1 & 2 150mm 225mm
Studio 3 150mm 225mm
2.1 When installed on a Stovax bench, the bench may
stand on a 12mm thick non-combustible hearth and it is
recommended that the 225mm hearth depth should be
increased to safely contain any falling logs or embers.
2.2 The building must have a suitable load-bearing capacity for
the hearth and appliance. Consult a structural engineer for
advice before proceeding.
2.3 When fitting into an existing hearth check that the
appliance complies with current construction regulations
and is at least the minimum sizes shown.
2.4 If there is no existing fireplace or chimney it is possible to
construct a suitable non-combustible housing and hearth
setting. The flue must be installed in accordance with all
local and national regulations and current rules in force.
Check if adding a new chimney to your property requires
planning permission.
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stovax Riva Studio Bench Glass and Steel at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stovax Riva Studio Bench Glass and Steel in the language / languages: English as an attachment in your email.

The manual is 1.31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info