THE CLEAN AIR ACT 1993 AND SMOKE CONTROL AREAS
The Clean Air Act 1993 and Smoke Control Areas
Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control area.
It is an offence to emit smoke from a chimney of a building, from a furnace or from any fixed boiler if located in a designated
smoke control area. It is also an offence to acquire an “unauthorised fuel” for use within a smoke control area unless it is used
in an “exempt” appliance (“exempted” from the controls which generally apply in the smoke control area).
In England appliances are exempted by publication on a list by the Secretary of State in accordance with changes made to
sections 20 and 21 of the Clean Air Act 1993 by section 15 of the Deregulation Act 2015. Similarly in Scotland appliances are
exempted by publication on a list by Scottish Ministers under section 50 of the Regulatory Reform (Scotland) Act 2014.
In Wales and Northern Ireland these are authorised by regulations made by Welsh Ministers and by the Department of the
Environment respectively.
Further information on the requirements of the Clean Air Act can be found here at:
https://www.gov.uk/smoke-control-area-rules
Refuelling to a low fire bed
If there is insufficient burning material in the firebed to light a new fuel charge, excessive smoke emission can occur. Refuelling
must be carried out onto a sufficient quantity of glowing embers and ash that the new fuel charge will ignite in a reasonable
period. If there are too few embers in the fire bed, add suitable kindling to prevent excessive smoke.
Fuel Overloading
The maximum amount of fuel specified in this manual should not be exceeded, overloading can cause excess smoke.
Operation with the door left open
Operation with the door open can cause excess smoke. The appliance must not be operated with the appliance door left open
except as directed in the instructions.
Air Controls left open
Warning: Do not operate the appliance with the Primary Air Control open for long periods of time as this could cause over-firing,
increased smoke emissions and may cause permanent damage.
CO Alarms
Building regulations require that whenever a new or replacement fixed solid fuel or wood/biomass appliance is installed in a
dwelling a carbon monoxide alarm, complying with BS EN50291, must be fitted in the same room as the appliance. Further
guidance on the installation of the carbon monoxide alarm is available in the latest edition of BS EN50292 and from the alarm
manufacturer's instructions.
Provision of an alarm must not be considered a substitute for either installing the appliance correctly or ensuring regular
servicing and maintenance of the appliance and chimney system.
The following Futura appliances (Model No:715-135/715-539/715-010/715-458/715-287) have been recommended as suitable for
use in smoke control areas when burning wood logs. These appliances (Model No:715-135/715-539/715-010/715-458/715-287) are
fitted with the appropriate permanent stop for the model (supplied by Stovax) to prevent full closure of the secondary air
inlet slots.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stovax Futura at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stovax Futura in the language / languages: English as an attachment in your email.

The manual is 1.71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Stovax Futura

Stovax Futura Additional guide - English - 2 pages

Stovax Futura Installation Guide - English - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info