English
30
Always use detergent in the
specified dosage – follow the
corresponding instructions for use
of the detergent.
Chemical detergents may contain
physiologically harmful (toxic,
caustic, irritant), flammable or
explosive substances. In the event
of skin or eye contact with
detergent, flush the affected body
parts with plenty of clean water
immediately. If detergent is
swallowed, seek medical attention
immediately. Note the
manufacturer's safety data sheets!
Before starting work
Only connect the high-pressure cleaner
to the drinking water main in conjunction
with a backflow preventer see "Special
accessories".
WARNING
If drinking water has passed
through the backflow preventer, it
can no longer be regarded as
drinking water.
Do not use the machine with dirty water.
If there is a risk that dirty water will occur
(e. g., flowing sand), an appropriate
water filter must be used.
Inspecting the high-pressure cleaner
WARNING
The high-pressure cleaner should
only be used if it is in full working
order – risk of accident!
It must be possible to move the
switch to the 0 position easily
The switch must be in the 0 position
Inspect the high-pressure hose,
spray attachment and safety
mechanisms for damage
High-pressure hose and spray
attachment in good condition
(clean, moving easily) and correctly
assembled
For good control of the machine, the
handles should be clean and dry
with no oil or dirt on them
Never attempt to modify the controls
or safety devices
Electrical connection
WARNING
Minimize the risk of electrical shock:
Voltage and frequency of the
machine (see rating plate) must
match the voltage and frequency of
the mains supply
Examine the power cord, power
plug and extension cord for
damage. Damaged cords,
couplings and plugs or power cords
that do not comply with the
regulations must not be used
Only connect the machine to a
correctly installed power socket
The insulation on the power cord
and any extension cord, the plug
and the coupling must be fully intact
Never touch the power plug, power
cord and extension cord and
electrical plug connections with wet
hands
WARNING
Route the power cord and extension
cord properly:
Observe the minimum cross-section
of the individual cords – see
"Connecting the machine to the
power supply"
Route and mark the power cord so
that it cannot become damaged and
no one is endangered – danger of
stumbling!
Use of unsuitable extension cords
can be dangerous. Use only
extension cords that are approved
for outdoor use and are
correspondingly marked and have a
sufficient cross-section
The connector and coupling of the
extension cord must be waterproof
and not lie in water
It is advisable to keep the plug
connection at least 60 mm above
the ground/floor, e. g. by using a
cable reel
don't let the cord rub against edges
or pointed or sharp objects
don't squeeze the cord under doors
or windows
Do not connect the high-
pressure cleaner directly
to the drinking water
main.
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stihl re 108 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stihl re 108 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 6,57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Stihl re 108

Stihl re 108 User Manual - English - 15 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info