164 MS 241 C
14.7.2 Summary of test connections and test values
The wires in the handle must be
unplugged to test the individual
components separately
1)
Pull wire out for this purpose
Component Ohmmeter
connection (either test
lead can be used)
Resistance Ω If faulty
Lead 1 Lead 2 Re-
quired
Actual Cause Remedy
Switch Switch
connection
1)
Switch
housing
< 0.5 - Switch faulty Replace switch
Heating element in
handle
Connector
to lead
from
heating
element
Connector
to lead
from
heating
element
1.6 1.5 - 2.0 Heating element
OK
- Break in wire,
heating element
damaged
Replace heating
element and/or
repair insulation
0 Short circuit due to
damaged insulation
Heating element in
front handle
Connector
to lead
from front
handle
heating
element
Connector
to lead
from front
handle
heating
element
6.4 6.0...8.0 Heating element
OK
- Break in wire,
heating element
damaged
Replace front
handle
0 Short circuit due to
damaged insulation
repair insulation
165


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stihl MS 241 C-M at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stihl MS 241 C-M in the language / languages: English as an attachment in your email.

The manual is 12,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Stihl MS 241 C-M

Stihl MS 241 C-M User Manual - German, Dutch, French, Italian - 220 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info